| поискавой системы для электроныых деталей |
|
GC5016 датащи(PDF) 21 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
GC5016 датащи(HTML) 21 Page - Texas Instruments |
|
21 / 88 page ![]() GC5016 SLWS142G − JANUARY 2003 − REVISED NOVEMBER 2005 www.ti.com 21 Number_of_clocks = cic_dec x fir_dec If the data stream is complex, then half the clock cycles are used computing the I output and half are used computing the Q output. The tap delay line limits the filter length to 256 if non-symmetric and 512 if symmetric (half this with complex data streams). The maximum number of taps is determined by the cmd5016 program. It can be estimated by: ntaps = sym x 16 x fir_dec x int(min(cic_dec,16/fir_dec)/(cmplx/fir_nchan)) − odd Where: cmplx = 1 for real data (or splitiq) and 2 for complex sym = 1 for nonsymmetric and 2 for symmetric odd = 1 for odd, symmetric filters fir_nchan = 1 for up and down conversion The PFIR coefficients are programmed using the cmd5016 configuration software.The cmd5016 program reports the maximum number of taps available for the configuration. The cmd5016 program uses the mode_ab(cd), splitiq, cic_dec, fir_dec, fir_diff, fir_nchan, and pfir_coef keywords to program the filters. If there are multiple filter sets, the number of filters stored in memory will limit the number of coefficients per set . The filter supports odd or even symmetry. If the user’s filter is significantly shorter than the maximum filter supported, the clock is stopped to the filter block, saving power. The filter coefficients are zero-appended to the allowable number of taps. The cmd5016 software in the .ANL extension file reports the number of taps in the user-specified filter file, the PFIR filter mode, and the number of PFIR taps in the programmed configuration. Gain for the FIR is: Gain = sum (coefficients) x 2(fir_shift − 21). The overall_gain pseudo-command is normally used to set the PFIR gain. There is an application note on DDC gain, and using cmd5016 has examples for specific applications of the PFIR for DDC usage. 13.8 Power Meter The PFIR output data is input to the power meter. The power meter integrates the I^2+Q^2 power over a number of PFIR output samples. The power meter output is read as a 32bit result over the Microprocessor port. The power meter squares the I or Q top 12 bits of the data, keeps the top 17 bits of the result, and integrates it for up to 216 words. The number of words is I or Q samples. Handshaking is provided to let the user know when data is ready. Note that the integration is over a number of words so if the data is complex the number of samples integrated is one half the number of words. If the filters are configured in a splitiq mode then the power meters of the real and imaginary channels need to be combined by reading both the I and Q channel power meters and adding the results.. A sync is available to start the power measurement period. The power meter automatically starts a new measurement at the conclusion of the last one. The contents of the power meter registers should be considered unstable from eight clocks after input sync to eight clocks plus an output sample time. (The actual unstable time is around 0.5 ns, so even reading during this window provides correct answers most of the time.) Reading during data transfer results in an erroneous output (some bits being updated, while others are not) but does no other harm. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |