| поискавой системы для электроныых деталей |
|
ST92196A датащи(PDF) 179 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
ST92196A датащи(HTML) 179 Page - STMicroelectronics |
|
179 / 268 page ![]() 179/268 - FOUR-CHANNEL I2C BUS INTERFACE (I2C) I2C BUS INTERFACE (Cont’d) Bit 1 = UNEXP Unexpected flag bit This bit is useful for error detection in a multimas- ter mode system, when a master is continuing its transaction while an other concurrent master wants to finish or restart a transaction by sending a “Start” or a “Stop” condition. Together with the MISP bit, it covers all possible cases, where unexpected “Start” or “Stop” condi- tions occur, while the interface is a master. 0: No Unexpected error detected 1: A master interface receives a “Start” or a “Stop” condition, while sending the first bit of a data byte. Notes: – If this bit is set, it will automatically activate the ERROR bit. – This bit is only valid when the Advanced Fea- tures Enable bit AFEN is set. Bit 0 = MISP Misplaced flag bit This bit indicates if the interface has received a misplaced “Start” or “Stop” condition during ad- dress transfer or any data byte transfer (besides first data bit). This error detection is also activated during the acknowledge bit transfer. Together with the UNEXP bit, it covers all possible cases, where unexpected “Start” or “Stop” condi- tions occur, while the interface is a master. 0: No misplaced “start” or “stop” condition has been detected 1: A misplaced “Start” or “Stop” condition has been received. Note: If this bit is set, it will automatically activate the ERROR bit. STATUS REGISTER 1 (I2CSTR1) R245 - Read Only Register Page: 44 Reset Value: 0000 0000(00h) Bit 7 = ERROR ERROR detection bit This bit indicates if an error occurred on the bus or not. 0: No error detected 1: An error is detected. It is an illegal start or stop condition, i.e. a signal level transition occurs on the SDA bus during presence of a clock pulse on the SCL bus. An interrupt is generated in this case. The inter- face stays in the error state until the error flag is reset by either a CLEAR operation, a STOP re- quest or a “Return To Inactive State” operation. Note: the ERROR bit has higher priority than the ARB_LOST bit (i.e. when ERROR=1, the value of ARB_LOST has to be ignored). 70 ERROR ARB_ LOST READ FIRST GEN_ CALL ACK_ BIT ACT_ SLV ACTIVE |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |