| поискавой системы для электроныых деталей |
|
EMC2101-R-ACZL-TR датащи(PDF) 20 Page - SMSC Corporation |
|
|
|||||||||||||||||||||||||||||
EMC2101-R-ACZL-TR датащи(HTML) 20 Page - SMSC Corporation |
|
20 / 57 page ![]() SMBus Fan Control with 1°C Accurate Temperature Monitoring Datasheet Revision 2.54 (06-16-09) 20 SMSC EMC2101 DATASHEET 5.1 Modes of Operation (EMC2101-R Only) The EMC2101-R has two modes of operation based on the pull-up resistor on the ALERT pin (see Table 5.1). The modes of operation are: 1. Host Configuration Mode - An SMBus Host configures the EMC2101-R upon startup to allow for polling for temperature or fan information or the user can use the ALERT pin interrupt to determine which action is required. 2. Automatic Configuration Mode - The EMC2101-R queries an SMBus compatible EEPROM located at a known address (see Section 4.9) and automatically loads its registers with the contents of the EEPROM. This mode does not require host intervention but a host can poll the device for temperature and fan information. 5.2 Power Up (EMC2101-R Only) The EMC2101-R (only) will power up with the fan driver set to either 100% duty cycle or 0% duty cycle, depending on the value of the pull-up resistor on the ALERT / TACH pin. (See Table 5.1.) It will remain in this state until either the Fan Setting Register is written or until the following activities have occurred: 1. The Fan Control Look-Up Table is loaded and the PROG bit is set to ‘0’ 2. The temperature monitoring block performs its first comparison against the Look-Up Table. If the Fan Control Look-Up Table is used, the EMC2101-R Fan Driver will be immediately set to the appropriate setting in the table based on the measured temperature. 5.3 Power Modes The EMC2101 supports multiple power modes that are user configurable. The temperature monitoring and fan control functions of the device are independent. The power modes are: 1. Normal - the temperature monitoring and fan driver circuits are both active. The device updates all temperature channels at the user programmed conversion rate (see Table 6.6). Every time the temperature is updated, the limits are checked and the fan driver is updated based on the values in the Fan Control Look-Up Table (if the Fan Control Look-Up Table is enabled). 2. Standby - the temperature monitoring and fan driver circuits are both disabled. The device will not update temperature data automatically and the fan output will be set to default drive. A one-shot Figure 5.2 System Diagram for EMC2101-R GPU DP DN SMDATA Thermal diode EMC2101-R SMCLK FAN ALERT Fan Drive Circuitry EEPROM or Host Internal Diode EEPROM Loader SMBus Client |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |