| поискавой системы для электроныых деталей |
|
EMC2113 датащи(PDF) 67 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
EMC2113 датащи(HTML) 67 Page - Microchip Technology |
|
67 / 88 page ![]() RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown Datasheet 2013 Microchip Technology Inc. DS20005251A-page 67 7.34 Look Up Table Configuration Register The Look Up Table Configuration Register controls the setup information for the temperature to fan drive look up table. APPLICATION NOTE: This register is duplicated at 50h as well as 7Dh for ease of programming using block write mode. Example: Set register 50h to unlock the table and register 7Dh to lock the table. The External Diode 2 channel is always used as the Temperature 2 input to the Fan Control Look Up Table. Bit 7 - USE_DTS_P1 - This bit determines whether the Pushed Temperature 1 Register is using DTS data. ‘0’ (default) - The Pushed Temperature 1 Register is not using DTS data. The contents of the Pushed Temperature 1 registers are standard temperature data. ‘1’ - The Pushed Temperature 1 Register is loaded with DTS data. The contents of this register are automatically subtracted from a fixed value of 100°C before being compared to the Look Up Table threshold levels. Bit 6 - USE_DTS_P2 - This bit determines whether the Pushed Temperature 2 Register is using DTS data. ‘0’ (default) - The Pushed Temperature 2 Register is not using DTS data. The contents of this register are standard 2’s complement temperature data. ‘1’ - The Pushed Temperature 2 Register is loaded with DTS data. The contents of this register are automatically subtracted from a fixed value of 100°C before being compared to the Look Up Table threshold levels. Bit 5 - LUT_LOCK - This bit locks updating the Look Up Table entries and determines whether the look up table is being used. ‘0’ (default) - The Look Up Table entries can be updated normally. The Look Up Table will not be used while the Look Up Table entries are unlocked. During this condition, the PWM output will not change states regardless of temperature or tachometer variation. where: [4] poles = number of poles of the fan (typically 2) n = number of edges measured (typically 5) m = the multiplier defined by the RANGE bits [5] COUNT = TACH Reading Register value (in decimal) Table 7.51 Look Up Table Configuration Register ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 50h R/W LUT Configuration USE_ DTS_P1 USE_ DTS_P2 LUT LOCK RPM / PWM PUSH1_ CFG TEMP1_ CFG TEMP3_ CFG TEMP4_ CFG 00h 7Dh RPM 1 poles -------------------- n 1 – COUNT 1 m ----- ---------------------------------- 1,966,080 = RPM 3,932,160 m COUNT -------------------------------------- = |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |