| поискавой системы для электроныых деталей |
|
EMC2103 датащи(PDF) 26 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
EMC2103 датащи(HTML) 26 Page - Microchip Technology |
|
26 / 85 page ![]() RPM-Based Fan Controller with Hardware Thermal Shutdown Datasheet 2013 Microchip Technology Inc. DS0005250A-page 26 5.2 Fan Control Modes of Operation The EMC2103 has four modes of operation for the fan driver. Each mode uses Ramp Rate control and the Spin Up Routine 1. PWM Setting Mode - in this mode of operation, the user directly controls the PWM duty cycle setting. Updating the Fan Driver Setting Register (see Section 6.20) will instantly update the fan drive. This is the default mode. The PWM Setting Mode is enabled by clearing both the EN_ALGO bit in the Fan Configuration Register (see Section 6.22) and the LUT_LOCK bit in the Look Up Table Configuration Register (see Section 6.32). Whenever the PWM Setting Mode is enabled the current drive will be changed to what was last written into the Fan Driver Setting Register. 2. Fan Speed Control Mode (FSC) - in this mode of operation, the user determines a fan speed and the drive setting is automatically updated to achieve this target speed. This mode is enabled by clearing the LUT_LOCK bit in the Look Up Table (LUT) Configuration Register and setting the EN_ALGO bit in the Fan Configuration Register. 3. Using the Look Up Table with Fan Drive Settings (PWM Setting w/ LUT Mode) - In this mode of operation, the user programs the Look Up Table with PWM duty cycle settings and corresponding temperature thresholds. The fan drive is set based on the measured temperatures and the corresponding drive settings. This mode is enabled by programming the Look Up Table then setting the LUT_LOCK bit while the RPM / PWM bit is set to a ‘1’ (see Section 6.32) 4. Using the Look Up Table with Fan Speed Control algorithm (FSC w/ LUT Mode)- In this mode of operation, the user programs the Look Up Table with fan speed target values and corresponding temperature thresholds. The TACH Target Register will be set based on the measured temperatures and the corresponding target settings. The PWM drive settings will be determined automatically based on the RPM based Fan Speed Control Algorithm This mode is enabled by programming the Look Up Table then setting the LUT_LOCK bit while the RPM / PWM bit is set to ‘0’ (see Section 6.32). 94 1020 126 29400 95 1100 127 49900 96 1150 65 Open Table 5.3 Fan Controls Active for Operating Mode DIRECT PWM SETTING MODE FSC MODE DIRECT PWM SETTING W/ LUT MODE FSC W/ LUT MODE Fan Driver Setting (read / write) Fan Driver Setting (read only) Fan Driver Setting (read only) Fan Driver Setting (read only) EDGES[1:0] EDGES[1:0] (Fan Configuration) EDGES[1:0] EDGES[1:0] - RANGE[1:0] (Fan Configuration) - RANGE[1:0] (Fan Configuration) UPDATE[2:0] (Fan Configuration) UPDATE[2:0] (Fan Configuration) UPDATE[2:0] (Fan Configuration) UPDATE[2:0] (Fan Configuration) Table 5.2 TRIP_SET Resistor Setting (continued) TTRIP (°C) RSET (1%) TTRIP (°C) RSET (1%) |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |