14 / 41 page ![]() System Initialization Whenever po wer is appl ied to the CS5516/CS5520 A/D converters, the devices must be reset to a known condition before proper operation can occur. The internal reset is applied after power is established and lasts for approximately 100 ms. The RST pin can also be used to establish a reset condition. The reset sig- nal should remain low for at least one XIN clock cycle to ensure adequate reset time. It is recom- mended that the RST pin be used to reset the converter if the power supplies rise very slowly or with poor startup characteristics. The RST signal can be generated by a microcontroller out- put, or by use of an R-C circuit. The reset function initializes the configuration register and all five of the calibration registers; and places the microcontroller in command mode ready to accept a command from the serial port. Whenever the device is reset the DRDY pin will be set to a logic 1 and the on-chip regis- ters are initialized to the following states: Configuration 000000(H) Calibration registers: DAC 000000(H) Gain 800000(H) AIN Ratiometric Offset 000000(H) AIN Non-ratiometric Offset 000000(H) VREF Non-ratiometric Offset 000000(H) CALIBRATION After the CS5516/20 is reset, the device is func- tional and can perform measurements without being calibrated. The converter will utilize the initialized values of the calibration registers to calculate output words. The converter uses the two outputs (AIN & VREF) of the dual channel converter along with the contents of the calibration registers to com- pute the conversion data word. The following equation indicates the computation. R0 = R4 [[ DAIN − R1 DVREF − R2] − R3 ] Where R0 is the output data, DAIN and DVREF are the digital output words from the AIN and VREF digital filter channels, and R1, R2, R3 and R4 are the contents of the following calibra- tion registers: R1 = AIN non-ratiometric offset R2 = VREF non-ratiometric offset R3 = AIN ratiometric offset R4 = Gain The computed output word, R0, is a two’s com- plement number. Calibration minimizes the errors in the converted output data. If calibration has not been per- formed, the measurements will include offset and gain errors of the entire system. The converter may be calibrated each time it is powered up, or calibration words from a pre- vious calibration may be uploaded into the appropriate calibration registers from some type of E 2PROM by the system microcontroller. The converter uses five different registers to store specific calibration information. Each of the calibration registers stores information perti- nent to correcting a specific source of error associated with either the converter or with the input transducer and its wiring. The method by CS5516, CS5520 14 DS74F1 14 DS74F2 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |