| поискавой системы для электроныых деталей |
|
RDC5028C датащи(PDF) 3 Page - Aeroflex Circuit Technology |
|
|
|||||||||||||||||||||||||||||
RDC5028C датащи(HTML) 3 Page - Aeroflex Circuit Technology |
|
3 / 20 page ![]() 3 SCD5028-2 Rev G 5/7/2014 Aeroflex Plainview PIN DESCRIPTIONS SIGNAL DIRECTION PIN SIGNAL DESCRIPTION +SIN -SIN INPUT 22 21 Analog Sine input from Synchro or Resolver. 1.3Vrms nominal +COS -COS INPUT 25 24 Analog Cosine input from Synchro or Resolver. 1.3Vrms nominal +REF -REF INPUT 11 12 Analog Reference input is typically a sine wave @ 1.3Vrms BIT 1 (MSB) BIT 2 BIT 3 BIT 4 BIT 5 BIT 6 BIT 7 BIT 8 BIT 9 BIT 10 BIT 11 BIT 12 BIT 13 BIT 14 BIT 15 BIT 16 (LSB) BIDIR 28 29 30 31 32 34 35 36 37 38 39 40 41 42 43 44 Digital angle data. Parallel format. Natural binary positive logic. Bit 1, most significant bit = 180°, Bit 2 = 90°, Bit 3 = 45° and so on. In the 10 bit mode, Bit 10 is the LSB. Bits 11-16 are 0s. In the 12 bit mode, Bit 12 is the LSB. Bits 13-16 are 0s. In the 14 bit mode, Bit 14 is the LSB. Bits 15-16 are 0s. In the 16 bit mode, Bit 16 is the LSB. SC1 SC2 INPUT 49 48 Digital input. Sets the resolution. SC1 SC2 Resolution 0 0 10 bit 0 1 12 bit 1 0 14 bit 1 1 16 bit ENABLE* INPUT 45 Logic 0 enables digital angle output. Otherwise it is high impedance. INH* INPUT 47 Logic 0 freezes the digital angle output so that it can be safely read. DATALOAD* INPUT 1 Logic 0 enables the digital angle lines to be inputs to preset the angle. Logic 1 is for normal digital angle output. BUSY OUTPUT 50 A logic 1 pulse when the digital angle changes by 1 LSB. CW/CCW OUTPUT 51 For turns counting. Logic 1 = counting up (CW), logic 0 = counting down (CCW). RIPPLE* OUTPUT 52 Ripple clock for turns counting. A logic 0 pulse = a 0° transition in either direction. AC1 AC2 OUTPUT 14 13 Differential AC error output BPF1 BPF2 INPUT 16 15 Differential AC error input to demodulator DEMOD1 DEMOD2 OUTPUT 17 18 Differential DC error output INTIN1 INTIN2 INPUT 8 6 Differential DC input to differential velocity integrator INT1 INT 2 OUTPUT 9 10 Differential velocity output VCOIN INPUT 5 Input to Voltage Controlled Oscillator VCC VDD POWER 4 27 Analog Power In Digital Power In A GND D GND POWER 3, 19, 23 26 Analog Power ground Digital Power ground VLI/O POWER 2 Digital input/output DC power supply. Sets logic 1 level. +3V to +5V * Indicates Active Low Signal |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |