| поискавой системы для электроныых деталей |
|
L9779WD датащи(PDF) 115 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L9779WD датащи(HTML) 115 Page - STMicroelectronics |
|
115 / 170 page ![]() DocID027452 Rev 5 115/170 L9779WD Functional description 169 Behaviour of AB1: – asynchronous reset to "0" with RST_UV – synchronous reset to "0" IF <WDA_INT> = '0' (EC < 5) – IF (AB1_CNT = 7) AND ((sequencer-run AND further error) OR soft-reset) THEN AB1 = 1 ELSE unchanged. Generation of a monitoring module reset The monitoring module may cause a reset at the pin [RST] named "monitoring module reset" in conjunction with the internal signal WD_RST. The generation of a monitoring module reset depends on the state of the bit <INIT_WDR>. <INIT_WDR> = '0' (reset state): If <INIT_WDR> = '0', the signal <WD_RST> remains always inactive '0' and the monitoring module can never generate a reset. The error counter can only be decremented via correct responses. If <INIT_WDR> = '0' the state of the reset counter <RST_CNT> remains unchanged when an ERROR COUNTER overflow occurs (description of the reset counter <RST_CNT> see below). <INIT_WDR> = '1': If <INIT_WDR> = '1', an ERROR COUNTER overflow activates a reset [RST] (signal <WD_RST> becomes active). The signal <WD_RST> becomes active (i.e. '1') due to an ERROR COUNTER overflow when the value of the 3 bit reset counter <RST_CNT(2-0)> is 0..6. If the value of <RST_CNT> = "111" and an ERROR COUNTER overflow occurs <WD_RST> remains inactive (i.e. '0') and no reset is generated. The "reset counter" <RST_CNT> is incremented by one during a sequencer-run due to an ERROR COUNTER overflow when <INIT_WDR> = '1' and <RST_CNT> is between 0 and 6. If <RST_CNT> = 7 and an ERROR COUNTER overflow occurs, the counter state remains 7. The counter can not be decremented and can only reset to zero by an active RST_UV signal. The occurrence of a monitoring module reset is indicated via the flag <WDG_RST> = '1'. Reading the flag via MSC clears it automatically. In effect maximum 7 monitoring module resets can be generated between 2 active RST_UV signal. (see also state table for <INIT_WDR> = '1' below). The state of the "reset counter" <RST_CNT> can be read via MSC but cannot be changed. In a factory test-mode the pin [WDA] is always active '0'; the internal signal <WDA_INT> is not changed by the factory test-modes. Table 51. State for <INIT_WDR> = 1 RST_CNT old “EC” > 7 and sequencer-run RST_CNT new WD_RST 000 .. 111 no = RST_CNT old ‘0’, no monitoring module reset 000 .. 110 yes = RST_CNT old + 1 ‘1’, thus monitoring module reset 111 yes = RST_CNT old =111 ‘0’, no monitoring module reset |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |