35 / 58 page ![]() L6751B Output voltage monitoring and protection Doc ID 024028 Rev 1 35/58 7.1 Overvoltage When the voltage sensed by VSEN and/or SVSEN surpasses the OV threshold, the control- ler acts in order to protect the load from excessive voltage levels avoiding any possible undershoot. To reach this target, a special sequence is performed as per the following list: – The reference performs a DVID transition down to 250 mV on the section which triggered the OV protection. – The PWMs of the section which triggered the protection are switched between HiZ and zero (ENDRV is kept high) in order to follow the voltage imposed by the DVID on-going. This limits the output voltage excursion, protects the load and assures no undershoot is generated (if Vout < 250 mV, the section is HiZ). – The PWMs of the non-involved section are set permanently to HiZ (ENDRV is kept low) in order to realize a HiZ condition. – OSC/ FLT pin is driven high. – Power supply or EN pin cycling is required to restart operation. If the cause of the failure is removed, the converter ends the transition with all PWMs in HiZ state and the output voltage of the section which triggered the protection lower than 250 mV. 7.2 Overcurrent and current monitor The overcurrent threshold must be programmed to a safe value, in order to be sure that each section does not enter OC during normal operation of the device. This value must take into consideration also the process spread and temperature variations of the sensing ele- ments (inductor DCR). Furthermore, since also the internal threshold spreads, the design must consider the mini- mum/maximum values of the threshold. 7.2.1 Multi-phase section The L6751B features two independent load indicator signals, IMON and ILIM, to properly manage OC protection, current monitoring and DPM. Both IMON and ILIM source a current proportional to the current delivered by the regulator, as follows: Equation 10 The IMON and ILIM pins are connected to GND through a resistor (RIMON and RILIM respec- tively), implementing a load indicator with different targets. ● IMON is used for current reporting purposes and for the DPM phase shedding. RIMON must be designed considering that IMAX must correspond to 1.24 V (for correct IMAX detection). ● ILIM is used for the overcurrent protection only. RILIM must be designed considering that the OC protection is triggered when V(ILIM)=2.5 V. In addition, the L6751B also performs per-phase OC protection. – Per-phase OC. Maximum information current per-phase (IINFOx) is internally limited to 35 μA. This end-of-scale current (IOC_TH) is compared with the information current generated I MON I LIM DCR R G ------------- I OUT ⋅ == |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |