| поискавой системы для электроныых деталей |
|
USB4624 датащи(PDF) 41 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
USB4624 датащи(HTML) 41 Page - Microchip Technology |
|
41 / 58 page ![]() USB 2.0 HSIC Hi-Speed 4-Port Hub Controller Datasheet 2014 Microchip Technology Inc. DS00001717A-page 41 8.2 SOF Clock Output The USB4624 provides an 8Khz clock output synchronized to the USB host SOFs. The SOF output is generated from the previous SOF packet on the USB line. The device includes an internal free running frame counter to generate internal start of frame and end of frame events. The internal counter is re- synchronized every time a successful packet is received and decoded. The internal counter is advanced to compensate for the packet decode time. If the incoming SOF jitters early or late, the jitter will be visible in the next frame SOF output clock rising edge. If one or two SOFs are missing, the SOF output will continue based on the internal frame counter. If more than two SOF are missing, the SOF output signal will stop. The clock is guaranteed to stop in a low state. When enabled or disabled, there will never be a short cycle. Figure 8.2 SOF Output Timing 8.3 Flex Connect This feature allows the upstream port to be swapped with downstream physical port 1. Only downstream port 1 can be swapped physically. Using port remapping, any logical port (number assignment) can be swapped with the upstream port (non-physical). Flex Connect is enabled/disabled via two control bits in the Connect Configuration Register. The FLEXCONNECT configuration bit switches the port, and EN_FLEX_MODE enables the mode. 8.3.1 Port Control Once EN_FLEX_MODE bit is set, the functions of certain pins change, as outlined below. If EN_FLEX_MODE is set and FLEXCONNECT is not set: 1. PRTPWR1 enters combined mode, becoming PRTPWR1/OCS1_N 2. SUSPEND outputs ‘0’ to keep any upstream power controller off If EN_FLEX_MODE is set and FLEXCONNECT is set: 1. The normal upstream VBUS pin becomes a don’t care 2. PRTPWR1 is forced to a ‘1’ in combined mode, keeping the port power on to the application processor. 3. SUSPEND becomes PRTPWR1/OCS1_N for the port power controller for the connector port Upstream HS USB Internal frame counter events SOF (kHz) SOF packet accepted EOF1 EOF2 SOF SOF packet accepted EOF1 EOF2 SOF |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |