| поискавой системы для электроныых деталей |
|
TAS5548DCAR датащи(PDF) 21 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
TAS5548DCAR датащи(HTML) 21 Page - Texas Instruments |
|
21 / 116 page ![]() TAS5548 www.ti.com SLES270A – NOVEMBER 2012 – REVISED APRIL 2015 Table 2. Values Set During Reset CONTROL SETTING Output mixer configuration 0xD0 bit 30 = 0 (remapped output mixer configuration) High pass Enabled Unmute from clock error Hard unmute Input automute Enabled Output automute Enabled Serial data interface format I2S, 24-bit Individual channel mute No channels are muted Automute delay 14.9 ms Automute threshold 1 < 8 bits Automute threshold 2 Same as automute threshold 1 Modulation limit 93.7% (Note: Some power stages require a lower modulation index) Six- or eight-channel configuration Eight channels Volume and mute update rate Volume ramp 42.6 ms Treble and bass slew rate Update every 1.31 ms Bank switching Manual bank selection is enabled Biquad coefficients Set to all pass Input mixer coefficients Input N → Channel N, no attenuation Output mixer coefficients Channel N → Output N, no attenuation Subwoofer sum into Ch1 and Ch2 Gain of 0 Ch1 and Ch2 sum in subwoofer Gain of 0 Bass and treble bypass/inline Bypass DRC bypass/inline Bypass DRC Default values Master volume Mute Individual channel volumes 0 dB All bass and treble indexes 0 dB Treble filter sets Filter set 3 Bass filter sets Filter set 3 Loudness Loudness disabled, default values AM interference mode enable Disabled AM interference mode IF 455 kHz AM interference mode select sequence 1 AM interference mode tuned frequency and 0000, BCD input mode After the initialization time, the TAS5548 starts the transition to the operational state with the master volume set at mute. Because the TAS5548 has an internal oscillator time base, following the release of reset, oscillator trim command is needed so the TAS5548 can detect the MCLK and data rate and perform the initialization sequences. The PWM outputs are held at a mute state until the master volume is set to a value other than mute via I2C. 7.3.6.2.2 Power Down (PDN) The TAS5548 can be placed into the power-down mode by holding the PDN terminal low. When the power-down mode is entered, both the PLL and the oscillator are shut down. Volume is immediately set to full attenuation (there is no ramp down). This control uses the PWM mute sequence that provides a low click and pop transition to a non PWM switching mute state. Copyright © 2012–2015, Texas Instruments Incorporated Submit Documentation Feedback 21 Product Folder Links: TAS5548 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |