| поискавой системы для электроныых деталей |
|
MT9V024 датащи(PDF) 29 Page - ON Semiconductor |
|
|
|||||||||||||||||||||||||||||
MT9V024 датащи(HTML) 29 Page - ON Semiconductor |
|
29 / 62 page ![]() MT9V024_DSRev. G Pub. 4/15 EN 28 ©Semiconductor Components Industries, LLC, 2015. MT9V024: 1/3-Inch Wide-VGA Digital Image Sensor Feature Description Pixel Integration Control Total Integration Total integration time is the result of coarse shutter width and fine shutter width regis- ters, and depends also on whether manual or automatic exposure is selected. The actual total integration time, tINT is defined as: tINT = tINTCoarse + tINTFint (EQ 2) = (number of rows of integration x row time) + (number of pixels of integration x pixel time) where: – Number of Rows of Integration (Auto Exposure Control: Enabled) When automatic exposure control (AEC) is enabled, the number of rows of integra- tion may vary from frame to frame, with the limits controlled by R0xAC (minimum coarse shutter width) and R0xAD (maximum coarse shutter width). – Number of Rows of Integration (Auto Exposure Control: Disabled) If AEC is disabled, the number of rows of integration equals the value in R0x0B. or If context B is enabled, the number of rows of integration equals the value in R0xD2. – Number of Pixels of Integration The number of fine shutter width pixels is independent of AEC mode (enabled or disabled): • Context A: the number of pixels of integration equals the value in R0xD5. • Context B: the number of pixels of integration equals the value in R0xD8. Row Timing Context A: Row time = (R0x04 + R0x05) master clock periods (EQ 3) Context B: Row time = (R0xCC + R0xCD) master clock periods (EQ 4) Typically, the value of the Coarse Shutter Width Total registers is limited to the number of rows per frame (which includes vertical blanking rows), such that the frame rate is not affected by the integration time. If the Coarse Shutter Width Total is increased beyond the total number of rows per frame, the user must add additional blanking rows using the Vertical Blanking registers as needed. See descriptions of the Vertical Blanking regis- ters, R0x06 and R0xCE in Table 1and Table 2 of the MT9V024 register reference. A second constraint is that tINT must be adjusted to avoid banding in the image from light flicker. Under 60Hz flicker, this means the frame time must be a multiple of 1/120 of a second. Under 50Hz flicker, the frame time must be a multiple of 1/100 of a second. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |