Back Button AS0260CSSC28SUD20 Datasheet HTML 26Page - ON Semiconductor AS0260CSSC28SUD20 Datasheet HTML 27Page - ON Semiconductor AS0260CSSC28SUD20 Datasheet HTML 28Page - ON Semiconductor AS0260CSSC28SUD20 Datasheet HTML 29Page - ON Semiconductor AS0260CSSC28SUD20 Datasheet HTML 30Page - ON Semiconductor AS0260CSSC28SUD20 Datasheet HTML 31Page - ON Semiconductor AS0260CSSC28SUD20 Datasheet HTML 32Page - ON Semiconductor AS0260CSSC28SUD20 Datasheet HTML 33Page - ON Semiconductor AS0260CSSC28SUD20 Datasheet HTML 34Page - ON Semiconductor Next Button
Zoom Inzoom in Zoom Outzoom out
 30 / 83 page
background image
AS0260 DS Rev. G Pub. 5/15 EN
30
©Semiconductor Components Industries, LLC, 2015.
AS0260: 1/6-Inch 1080P High-Definition (HD) System-On-A-Chip (SOC) Digi-
tal Image Sensor
Figure 23:
Gamma Reference Variables Against Brightness Metric
ON Semiconductor recommends that cam_ll_start_contrast_bm is set at 100lux and
cam_ll_stop_contrast_bm is set at 20lux, but the actual setting is at the discretion of the
user.
The recommended setting for cam_ll_llmode is 0x03. This allows the AS0260 to calculate
both of the 19 knee point curves based on the user inputs, otherwise the user will have to
program the 19 knee point curves.
Gamma Curve Selection
The AS0260 allows the user to select between the two-curve interpolation mode or fixed
mode using either of the curves
Table 7:
Gamma Curve Selection
Variable
Name
Function
VAR(0x0F,0x0008) or
(R0xBC08)
ll_gamma_select
0x00= Auto curve select. The curves will interpolate based on
settings of cam_ll_start_contrast_bm and
cam_ll_stop_contrast_bm
0x01 = Contrast
curve is only used
0x02 =Noise
reduction curve is only used
Cam_ll_inv_brightness_metric
Bright
Light
Low
Light
Cam_ll_stop_contrast_percentage=25
Cam_ll_start_contrast_luma_percentage=80
Cam_ll_start_contrast_gradient=50
Cam_ll_stop_contrast_gradient=38



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83


датащи скачать

Go To PDF Page


ссылки URL



Вашему бизинису помогли Аллдатащит?  [ DONATE ] 

Что такое Аллдатащит   |   реклама   |   контакт   |   Конфиденциальность   |   Ссылка на техническое описание    |   обмен ссыками   |   поиск по производителю
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com