15 / 77 page ![]() AR0330_DS Rev. U Pub. 4/15 EN 15 ©Semiconductor Components Industries, LLC,2015. AR0330: 1/3-Inch CMOS Digital Image Sensor Sensor Initialization Sensor Initialization Power-Up Sequence The recommended power-up sequence for the AR0330CS is shown in Figure 6. The available power supplies (VDD_IO, VDD_PLL, VDD_MIPI, VAA, VAA_PIX) must have the separation specified below. 1. Turn on VDD_PLL and VDD_MIPI power supplies 2. After 100s, turn on VAA and VAA_PIX power supply. 3. After 10s, turn on VDD power supply. 4. After 10s, turn on VDD_IO power supply. 5. After the last power supply is stable, enable EXTCLK. 6. Assert RESET_BAR for at least 1ms. 7. Wait 150,000 EXTCLK periods (for internal initialization into software standby. 8. Write R0x3152 = 0xA114 to configure the internal register initialization process. 9. Write R0x304A = 0x0070 to start the internal register initialization process. 10. Wait 150,000 EXTCLK periods 11. Configure PLL, output, and image settings to desired values. 12. Wait 1ms for the PLL to lock. 13. Set streaming mode (R0x301A[2] = 1). Figure 6: Power Up Notes: 1. A software reset (R0x301A[0] = 1) is not necessary after the procedure described above since a Hard Reset will automatically triggers a software reset. Independently executing a software reset, should be followed by steps seven through thirteen above 2. The sensor must be receiving the external input clock (EXTCLK) before the reset pin is toggled. The sensor will begin an internal initialization sequence when the reset pin toggle from LOW to HIGH. This initialization sequence will run using the external input clock. Power on default state is soft- ware standby state, need to apply two-wire serial commands to start streaming. Above power up sequence is a general power up sequence. For different interface configurations, MIPI, and Parallel, some power rails are not needed. Those not needed power rails should be ignored in the general power up sequence. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |