35 / 39 page ![]() AN4038 Conclusion Doc ID 022686 Rev 1 35/39 7 Conclusion This proximity sensor guideline gives some indications of the parameters to consider when developing a proximity application. Results from the tests presented in this application note, advise designers to find the best compromise between sensitivity, stability, and noise immunity. 7.1 Practical example An example is given below of how to design two electrodes which have a size constraint. ● Electrode #1, size constraint = 50 mm2 ● Electrode #2, size constraint = 300 mm2 In accordance with the recommendations given in this application note, to obtain the best detection range and the least noise amplitude, the following parameters for Electrode #1 and Electrode #2 are proposed. Electrode #1 ● Because of its small size, increase the spacing between the Tx/Rx electrodes as much as possible. This should improve detection distance and increase noise. The best compromise is to favor the best detection distance. Take care not to space the electrodes too far apart as this can create a projected capacitance which is too small. If this happens, STM8TL5xxx devices are not be able to compensate part of the projected capacitance with the EPCC to achieve the target reference. Consequently, the EPCC will be out of the recommended range (see Section 3.4: Electrode parasitic capacitance compensation (EPCC) and can lead to an unstable proximity system. Electrode spacing selected: 4 mm. ● Increase the Rx/Tx electrode length to improve the detection distance and decrease the noise by increasing the projected capacitance. Electrode length selected: 7mm ● Chose an electrode width which does not penalize the detection distance and does not increase noise. Electrode width selected: 1.5 mm. ● Reduce the target reference as much as possible to reduce noise, but check the EPCC value is in the recommended range. The target reference selected is 1000 and the threshold setup is in accordance with the noise standard deviation recommendation. Electrode #2 ● With a big electrode, increase the Rx/Tx length to improve detection distance and reduce noise. Electrode length selected: 35 mm ● Increase the spacing between the Tx and Rx electrodes to improve the detection range. Note that increasing the spacing increases noise: always give preference to increasing electrode length before electrode spacing. Electrode spacing selected: 5 mm. ● Chose an electrode width which does not penalize the detection distance or increase noise. Electrode width selected: 1.5 mm. Figure 34 shows the parameters chosen for electrodes #1 and #2. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |