| поискавой системы для электроныых деталей |
|
AN4450 датащи(PDF) 24 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
AN4450 датащи(HTML) 24 Page - STMicroelectronics |
|
24 / 26 page ![]() Software AN4450 24/26 DocID025978 Rev 1 Follow this sequence: 1. Turn on BOOT bit (bit[7] =1 of CTRL_REG2 (0x21)) 2. Wait for the BOOT bit to reset (BOOT bit is self-clearing, it is set again to '0' by hardware at the end of the process) 3. Wait an additional 5 ms 4. Configure the registers 5. Power on the device for normal use 6.7 Absolute accuracy drift due to soldering Reflow soldering may cause a spread of the device population accuracy. The spread is PCB construction, assembly and layout specific. Beware that board warping may cause additional drift in the accuracy. If very good absolute accuracy is required, a one-point calibration in the production line could be implemented. 6.7.1 Correcting soldering drift (one-point calibration) The following is a brief guideline to reduce the impact of soldering. 1. Soldering drift is a complex process and it is not easy to identify the single root cause of soldering stress. 2. We define the soldering drift as the difference between the accuracy of the pressure sensor before and after soldering. 3. Soldering temperature profile is one of the major contributors to soldering shift. 4. A well-controlled temperature soldering profile, that avoids peak temperature over the max JEDEC spec can reduce the accuracy drift. Here some hints on how to minimize post-soldering drift in SW: 1. Be sure to re-hydrate the device package by keeping it at 70%RH for 12 h or waiting a minimum of 36 h at ambient humidity. 2. After point 1, if a residual drift is still present and above the application intended limits, perform a one-point calibration by following these steps: a) During board final test use a precision barometer to get the reference value and calculate the difference with respect to the sensor measurements (taken at maximum resolution) b) Store the difference (offset) in the application non-volatile memory c) Use the offset value to correct all measurements from the sensor d) Correction can be performed entirely by SW, or the offset value (upper 16-bit only) can be written in dedicated registers of the sensor (RPDSx), at each power-on, so that the values read from the sensor are already corrected e) When the device is calibrated after soldering as proposed above, thanks to the embedded quadratic compensation, the absolute accuracy is within +/-1 hPa f) The SW offset correction could also take into account for sensor aging test results. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |