12 / 26 page ![]() Power supply: consumption estimation and optimization AN4450 12/26 DocID025978 Rev 1 3 Power supply: consumption estimation and optimization There are 2 supply voltages in the LPS25H: VDD and VDD_IO. VDD is the core voltage used to supply to the internal circuits, power on reset, and the sensor. VDD_IO is the supply for the I2C / SPI blocks and interface signals. In order to prevent possible leakage in the operational condition, it is necessary to ensure VDD_IO <= VDD. The operating voltage for both VDD_IO and VDD is 1.7 V to 3.6 V. The LPS25H can also be powered directly by a small lithium coin battery like the CR2032. This type of battery has a current capability of 220 mAh, enough to sustain the sensor peak current (less than 1 mA). Provided that the battery fluctuation, which could be in the range of 0.4 V, is within the “normal operating voltage conditions” (even with an aged battery) and the recommended decoupling capacitors are placed near the sensor, our tests with batteries and switched resistive loads show that the sensor functions correctly even with fast slew rates. During the main power-on transition, the system will initialize the internal registers according to the factory-stored information (such as sensor calibration data). This is triggered by VDD increasing above 1.6 V. Current consumption during the device initialization peaks around 200 µA (for a duration of about 600 µs). After these steps, the LPS25H will enter a power-down state. The LPS25H is ready in power-down from power-off in about 2.5 ms. The LPS25H runs in normal mode from power-down state (toggling PD bit[7] in CTRL_REG1, 0x20) in a few microseconds. Depending on register RES_CONF (0x10) settings, the first valid measurement is ready after about 2 ms (minimum resolution, with AVGT[1:0]=00; AVGP[1:0]=00, i.e. 8+8 samples) or about 37 ms (maximum resolution, with AVGT[1:0]=11; AVGP[1:0]=11, i.e. 64+512 samples). The typical conversion time (with +/-3% accuracy at room temperature) is given by the formula: Equation 1 Tconversion in µs = 62 * (Tavg + Pavg) + 975 where Tavg and Pavg are the values, respectively, for temperature and for pressure measurements, selected in register RES_CONF as the number of averaged samples per measurement. – Example: Tavg = 64; Pavg = 512; Typ. conversion time 36687 µs The LPS25H has been designed to have a very low power consumption. The majority of the internal blocks are switched-on only during the acquisition time. In one-shot mode the device automatically goes into standby when the measurement is completed. The minimum power consumption occurs when the device is in power-down (PD=0 bit[7] of the CTRL_REG1 (0x20)) AND the interrupt pin is not configured to drain current. In normal |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |