Back Button AN2950 Datasheet HTML 29Page - STMicroelectronics AN2950 Datasheet HTML 30Page - STMicroelectronics AN2950 Datasheet HTML 31Page - STMicroelectronics AN2950 Datasheet HTML 32Page - STMicroelectronics AN2950 Datasheet HTML 33Page - STMicroelectronics AN2950 Datasheet HTML 34Page - STMicroelectronics AN2950 Datasheet HTML 35Page - STMicroelectronics AN2950 Datasheet HTML 36Page - STMicroelectronics AN2950 Datasheet HTML 37Page - STMicroelectronics  
Zoom Inzoom in Zoom Outzoom out
 33 / 37 page
background image
AN2950
Test equipment and measurement of efficiency and low load performance
Doc ID 15494 Rev 1
33/37
Figure 52.
Suggested connection for low power measurements (switch in position 1)
In this case, it is advisable to connect the switch shown in Figure 51 to position 2 (see
simplified scheme in Figure 53): the UUT's input voltage is measured directly to the UUT's
input terminal and the input current does not affect the measured input voltage.
Figure 53.
Suggested connection for high power measurements
(switch in position 2)
With this setting, the measurement error is introduced by the shunt resistance of the
voltmeter, which is not infinite and then causes a leakage current inside the voltmeter itself.
This current is measured by the ammeter together with the UUT's input current, but the error
is negligible at heavy loads, when the UUT's input current is much higher than the
voltmeter's leakage current.
On the other hand, at low load conditions, when the UUT's input current decreases and
approaches the voltmeter's leakage current, the measurement error introduced with this
setting becomes significant.
To conclude, we could say that the setting shown in Figure 52 should be used for low loads
and stand-by measurements, the setting shown in Figure 53 for heavy loads and efficiency
measurements. In you are not sure which measurement scheme has the least effect on the
results, you can try with both and register the input power's lower value.
As noted in IEC 62301, instantaneous measurements are appropriate when power readings
are stable. The UUT should be operated at 100% of the nameplate output current output for
at least 30 minutes (warm-up period) immediately prior to conducting efficiency
measurements. After this warm-up period, the AC input power should be monitored for a
period of 5 minutes to assess the stability of the UUT.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37


датащи скачать

Go To PDF Page


ссылки URL



Вашему бизинису помогли Аллдатащит?  [ DONATE ] 

Что такое Аллдатащит   |   реклама   |   контакт   |   Конфиденциальность   |   Ссылка на техническое описание    |   обмен ссыками   |   поиск по производителю
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com