| поискавой системы для электроныых деталей |
|
AN2864 датащи(PDF) 24 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
AN2864 датащи(HTML) 24 Page - STMicroelectronics |
|
24 / 29 page ![]() Testing the board AN2864 24/29 Doc ID 15282 Rev 1 3.7 Output overvoltage protection Output over-voltage protection is implemented by monitoring the voltage across the auxiliary winding during the MOSFET off time through the D2 diode and the resistor dividers R3 and R14 (see schematic in Figure 2), which are connected to the CONT pin of the VIPER17L. If the voltage on the CONT pin exceeds the VOVP thresholds (3 V typ.), an overvoltage event is assumed and the device is no longer allowed to switch. To re-enable the operation, the VDD voltage must be recycled. In order to provide high noise immunity and avoid spikes erroneously triggering the protection, a digital filter is implemented so that the CONT pin has to sense a voltage higher than the VOVP for four consecutive cycles before stopping the operation. Figure 23. OVP circuit The value of the output voltage when the protection should be triggered can be set through proper selection of the resistor dividers R3 and R14. While R3 is selected with consideration to the maximum power that the converter has to manage, R14 is selected according to the following formula. Equation 2 The protection is tested by disconnecting the opto-coupler from the feedback pin and light loading the converter. In this way the converter operates in open loop and delivers the most power possible. The excess power over the load charges the output capacitance, increasing the output voltage, since the OVP is tripped and the converter stops working. In Figure 24 it can be observed that the output voltage (Ch1, yellow waveform) increases and as it reaches the value of 6.6 V the converter stops switching. In the same figure the CONT pin voltage (Ch3, magenta waveform) and the drain current (Ch4, green waveform) are shown. The crest value of the CONT pin voltage tracks the output voltage. In Figure 25, the last switching cycles before the protection is triggered are reported in detail. Current Limit C ompa rator OVP DETECTION LOGI C Rlim Dov p (D 2) Aux iliary winding F rom SenseF ET To OVP Protection To PWM Logic Curr. Lim . BLOCK (R2) CONT PIN R ov p (R14) ⎟⎟ ⎠ ⎞ ⎜⎜ ⎝ ⎛ − − ⋅ ⋅ = V 3 V V N N V 3 R R ) 2 D _( ovp D _ drop OVP _ OUT s AUX ) 2 R _( LIM ) 14 R _( OVP |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |