| поискавой системы для электроныых деталей |
|
UM1545 датащи(PDF) 41 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
UM1545 датащи(HTML) 41 Page - STMicroelectronics |
|
41 / 64 page ![]() UM1545 F.A.Q.s Doc ID 023225 Rev 1 41/64 Q: "I'm not comfortable with hexadecimal notation when editing the coefficient values in the control panel. Can I use the floating point one?" A: Of course: uncheck Show Values in Hexadecimal in the preference window and you'll be able to enter the values in decimal notation. Please be aware that the floating point notation implies a long number of significant decimal digits that cannot be displayed all at once. As a result some digits might be hidden from view but can be easily displayed by highlighting the whole number with the mouse. Please remember that the coefficients range is from -1 to 1. Q: "The reset pulse length applied by default using the RESET command in the script does not fit my needs. Can I set a different value?" A: "There's no direct way to change the reset pulse length in a script. However, the reset procedure can be manually executed using the SET_RST command to move the reset line. Just use the following syntax: The reset pulse will now last 200 milliseconds. This value can be changed as needed. Q: "I want to add a note in the log to mark a section of interest for my work. How do I do that?" A: Follow this procedure: 1. Press the Add Note button in the Log Viewer window. 2. Write the note and press enter. The note will be immediately displayed. 4.2 Problems Q: "The device does not respond to the APW controls" A: The possible causes are: a. The device might be in standby. b. The device may need to be initialized. c. The Auto Apply option is unchecked. Q: "I do not get any I2C failure message, but I keep reading 00h or FFh. What's wrong?" A: The possible causes are: a. The interface board is not properly connected to the ST Sound Terminal® device board. b. The interface board is not correctly powered. Q: "I'm importing a LinearX LEAP© generated file but the import procedure always skips a filter. What's wrong?" A: The possible causes are: a. The Disable auto-scaler option is selected and one of the coefficients is out of range. b. One filter might be unstable and to avoid dangerous effects it is not applied to the device. SET_RST 0 # set RESET line at 0 (low_level) P 200 # pause 200 ms SET_RST 1 # set RESET line at 1 (high level) |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |