18 / 26 page ![]() Fast digital calibration procedure AN2299 18/26 Rev2 Eq. 8, Eq. 9 and Eq. 10 a pair of final 8-bits calibration data can be calculated as shown below: where XV and XI are those calculated in one of the four previous cases. 3.3.5 Coherency check One assumes that the EM works correctly and that built-in voltage and current sensors allow the target power sensitivity constant to be achieved, because the correction parameters Ki and Kv can tune measured values within the calibration range of ±12.5% per voltage or current channel. If after the calibration, calculated values for Cv or Ci are out of range (less than 0 or more than 255), it could mean that the application cannot reach the target value of power sensitivity. In this case, steps 3 and 4 have to be repeated choosing a smaller power sensitivity value. If the values of Cv or Ci are out of range even for small values of PM it could mean that the energy meter board is not good enough to perform such measurements, maybe because the tolerance of the components is too big, or no care has been taken in the layout phase, so the application has to be re-designed. Otherwise, if calibrators values are written into STPM01, the average RMS readings will be very close to target values XI and XV and the frequency of LED output will be very close to target value f. 3.4 Two current channels calibration If the meter uses two current sensors, calibration procedure must be repeated twice, one for each current channel calibration. Steps 1 to 3 of fast digital calibration procedure (working point setting, algorithm choice and calculation of offline parameters) must be followed as explained before and they are common for both channels. Before running the online procedure, configuration bit 7 must be cleared (PST2 = 0) to disable tamper function, then calibration is split for the two channels: ● Primary channel calibration: mode signal CSEL must be cleared to select primary channel, then step 4 and 5 (online measure and coherency check) must be executed. If Cv and Ci are valid values they can be written in bytes CHV and CHP. ● Secondary channel calibration: mode signal CSEL must be set to select secondary channel, then step 4 and 5 (online measure and coherency check) must be executed. This time only Ci, if valid, should be written in byte CHS. For more info see STPM01 datasheet, "Configuration bytes" paragraph. Ci 896 Xi I A ----- • 768 – = Eq. 29 Cv 896 Xv V A ------ • 768 – = Eq. 30 |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |