| поискавой системы для электроныых деталей |
|
CS5360 датащи(PDF) 14 Page - Cirrus Logic |
|
|
|||||||||||||||||||||||||||||
CS5360 датащи(HTML) 14 Page - Cirrus Logic |
|
14 / 22 page ![]() CS5360 14 DS280PP2 4.7 Power-Down The CS5360 has a power-down mode wherein typ- ical consumption drops to 1.0 mW. This is initiated when a loss of clock is detected (either LRCK or MCLK in Slave Mode or MCLK in Master Mode), RST is enabled or DIF0 / DIF1 are at a logic 1. The initialization sequence will begin whenever valid clocks are restored, RST is disabled and DIF0 / DIF1 are restored. If the MCLK / LRCK frequency ratio changes during power-down, the CS5360 will adapt to these new operating conditions. However, only the RST method of power-down will include the Master/Slave decision in the initialization se- quence. 4.8 Grounding and Power Supply Decoupling As with any high resolution converter, the CS5360 requires careful attention to power supply and grounding arrangements to optimize performance. Figure6 shows the recommended power arrange- ments with VA+ connected to a clean +5volt sup- ply. VD+ should be derived from VA+ through a 2 ohm resistor. VD+ should not be used to power ad- ditional digital circuitry. All mode pins which re- quire VD+ should be connected to pin 6 of the CS5360. All mode pins which require DGND should be connected to pin 5 of the CS5360. AGND and DGND, Pins 4 and 5, should be con- nected together at the CS5360. DGND for the CS5360 should not be confused with the ground for the digital section of the system. The CS5360 should be positioned over the analog ground plane near the digital / analog ground plane split. The an- alog and digital ground planes must be connected elsewhere in the system. The CS5360 evaluation board, CDB5360, demonstrates this layout tech- nique. This technique minimizes digital noise and insures proper power supply matching and se- quencing. Decoupling capacitors should be located as near to the CS5360 as possible. 4.9 Digital Filter Figures 12-15 show the performance of the digital filter included in the CS5360. All plots are normal- ized to Fs. Assuming a sample rate of 48 kHz, the 0.5 frequency point on the plot refers to 24 kHz. The filter frequency response scales precisely with the sample rate. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |