| поискавой системы для электроныых деталей |
|
AD5686 датащи(PDF) 19 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD5686 датащи(HTML) 19 Page - Analog Devices |
|
19 / 24 page ![]() Data Sheet AD5696/AD5694 Rev. A | Page 19 of 24 READ OPERATION When reading data back from the AD5696/AD5694, the user must begin with a start command followed by an address byte (R/W = 0), after which the DAC acknowledges that it is prepared to receive data by pulling SDA low. The address byte must be followed by the command byte, which determines both the read command that is to follow and the pointer address to read from; the command byte is also acknowledged by the DAC. The user configures the channel to read back the contents of one or more DAC registers and sets the readback command to active using the command byte. Following this, the master establishes a repeated start condition, and the address is resent with R/W = 1. This byte is acknowledged by the DAC, indicating that it is prepared to transmit data. Two bytes of data are then read from the DAC, as shown in Figure 38. A NACK condition from the master, followed by a stop condition, completes the read sequence. If more than one DAC is selected, Channel A is read back by default. MULTIPLE DAC READBACK SEQUENCE When reading data back from multiple AD5696/AD5694 DACs, the user begins with an address byte (R/W = 0), after which the DAC acknowledges that it is prepared to receive data by pulling SDA low. The address byte must be followed by the command byte, which is also acknowledged by the DAC. The user selects the first channel to read back using the command byte. Following this, the master establishes a repeated start condition, and the address is resent with R/W = 1. This byte is acknowledged by the DAC, indicating that it is prepared to transmit data. The first two bytes of data are then read from DAC Input Register n (selected using the command byte), most significant byte first, as shown in Figure 38. The next two bytes read back are the contents of DAC Input Register n + 1, and the next bytes read back are the contents of DAC Input Register n + 2. Data is read from the DAC input registers in this auto-incremented fashion until a NACK followed by a stop condition follows. If the contents of DAC Input Register D are read out, the next two bytes of data that are read are the contents of DAC Input Register A. Figure 38. I2C Read Operation FRAME 2 COMMAND BYTE FRAME 1 SLAVE ADDRESS 1 1 0 0 0 1 A1 A0 R/W DB23 DB22 DB21 DB20 DB19 DB18 DB17 DB16 9 9 1 START BY MASTER ACK BY AD5696/AD5694 ACK BY AD5696/AD5694 SCL SCL SDA 1 9 9 1 1 9 9 1 ACK BY AD5696/AD5694 REPEATED START BY MASTER ACK BY MASTER FRAME 4 MOST SIGNIFICANT DATA BYTE n FRAME 3 SLAVE ADDRESS ACK BY MASTER NACK BY MASTER STOP BY MASTER FRAME 6 MOST SIGNIFICANT DATA BYTE n + 1 FRAME 5 LEAST SIGNIFICANT DATA BYTE n 1 0 0 0 1 A1 A0 R/W DB15 DB14 DB13 DB12 DB11 DB10 DB9 DB8 SDA SCL (CONTINUED) SDA (CONTINUED) DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0 DB15 DB14 DB13 DB12 DB11 DB10 DB9 DB8 |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |