18 / 35 page ![]() LM628, LM629 SNVS781C – JUNE 1999 – REVISED MARCH 2013 www.ti.com The derivative-term sampling interval is also programmable via this command. After writing the command code, the first two data bytes that are written specify the derivative-term sampling interval and which of the four filter parameters is/are to be written via any forthcoming data bytes. The first byte written is the more significant. Thus the two data bytes constitute a filter control word that informs the LM628 as to the nature and number of any following data bytes. See Table 4. Table 4. Filter Control word Bit Allocation Bit Position Function Bit 15 Derivative Sampling Interval Bit 7 Bit 14 Derivative Sampling Interval Bit 6 Bit 13 Derivative Sampling Interval Bit 5 Bit 12 Derivative Sampling Interval Bit 4 Bit 11 Derivative Sampling Interval Bit 3 Bit 10 Derivative Sampling Interval Bit 2 Bit 9 Derivative Sampling Interval Bit 1 Bit 8 Derivative Sampling Interval Bit 0 Bit 7 Not Used Bit 6 Not Used Bit 5 Not Used Bit 4 Not Used Bit 3 Loading kp Data Bit 2 Loading ki Data Bit 1 Loading kd Data Bit 0 Loading il Data Bits 8 through 15 select the derivative-term sampling interval. See Table 5. The user must locally save and restore these bits during successive writes of the filter control word. Bits 4 through 7 of the filter control word are not used. Bits 0 to 3 inform the LM628 as to whether any or all of the filter parameters are about to be written. The user may choose to update any or all (or none) of the filter parameters. Those chosen for updating are so indicated by logic one(s) in the corresponding bit position(s) of the filter control word. The data bytes specified by and immediately following the filter control word are written in pairs to comprise 16- bit words. The order of sending the data words to the LM628 corresponds to the descending order shown in the above description of the filter control word; i.e., beginning with kp, then ki, kd and il. The first byte of each word is the more-significant byte. Prior to writing a word (byte pair) it is necessary to check the busy bit in the status byte for readiness. The required data is written to the primary buffers of a double-buffered scheme by the above described operations; it is not transferred to the secondary (working) registers until the UDF command is executed. This fact can be used advantageously; the user can input numerous data ahead of their actual use. This simple pipeline effect can relieve potential host computer data communications bottlenecks, and facilitates easier synchronization of multiple-axis controls. UDF COMMAND: UPDATE FILTER Command Code: 04 Hex Data Bytes: None Executable During Motion: Yes The UDF command is used to update the filter parameters, the specifics of which have been programmed via the LFIL command. Any or all parameters (derivative-term sampling interval, kp, ki, kd, and/or il) may be changed by the appropriate command(s), but command UDF must be executed to affect the change in filter tuning. Filter updating is synchronized with the calculations to eliminate erratic or spurious behavior. 18 Submit Documentation Feedback Copyright © 1999–2013, Texas Instruments Incorporated Product Folder Links: LM628 LM629 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |