| поискавой системы для электроныых деталей |
|
AM79C984 датащи(PDF) 17 Page - Advanced Micro Devices |
|
|
|||||||||||||||||||||||||||||
AM79C984 датащи(HTML) 17 Page - Advanced Micro Devices |
|
17 / 44 page ![]() P R E L I M I N A R Y Am79C984A 17 external filter modules. Proper termination is shown in the Systems Applications section. The receiver’s threshold voltage can be programmed to an extended-distance mode. In this mode, the differen- tial receiver’s threshold is reduced to allow a longer cable than the 100 meters specified in the IEEE 802.3 standard. For programming details, refer to the Control Commands section. Link Test The integrated TP ports implement the Link Test func- tion, as specified in the IEEE 802.3 10BASE-T stan- dard. The eIMR device will transmit Link Test pulses to any TP port after that port’s transmitter has been inac- tive for more than 8 ms to 17 ms. Conversely, if a TP port does not receive any data packets or Link Test pulses for more than 65 ms to 132 ms and the Link Test function is enabled for that port, then that port will enter the link-fail state. The eIMR device will disable a port in link-fail state (i.e., disable repeater transmit and receive functions) until it receives either four consecutive Link Test pulses or a data packet. The Link Test function can be disabled via the eIMR control port on a port-by-port basis, to allow the eIMR device to operate with pre-10BASE-T networks that do not implement the Link Test function. When the Link Test function is disabled, the eIMR device will not allow the TP port to enter link-fail state, even if no Link Test pulses or data packets are being received. Note, how- ever, that the eIMR device will always transmit Link Test pulses to all TP ports, regardless of whether or not the port is enabled, partitioned, in link-fail state, or has its Link Test function disabled. Separate control com- mands exist for enabling and disabling the transmission of Link Test pulses on a port-by-port basis. Polarity Reversal The TP ports can be programmed to receive data if a wiring error results in a data packet being received at a TP port with reversed polarity. This function will be en- abled upon reception of a negative End Transmit Delim- iter (ETD) or negative pulses and allows subsequent packets to be received with the correct polarity. The po- larity-reversal function is executed once following reset or link-fail and can be programmed via the control port to be enabled or disabled on a port-by-port basis. The function may be enabled or disabled, following a reset, depending on the level of the SI signal on the rising edge of the RST pulse. Visual Status Monitoring (LED) Support The eIMR status port can be connected to LEDs to fa- cilitate the visual monitoring of repeater port status. The status port has twelve output signals, LDA0-4, and LDB0-4, LDGA, and LDGB. LDA0-4 and LDB0-4 repre- sent the four TP ports and AUI port. LDGA and LDGB are global indicators. Attributes that may be monitored are Carrier Sense (CRS), Collision (COL), Partition (PAR), Link Status (LINK), Loopback (LB), Port Dis- abled (DIS), and Jabber (JAB). Three control bits, LDC0-2, select the particular attributes to be displayed on the LEDs. Table 2 shows how the programming combinations for LDC0-2 control the attributes that will be monitored. Each LED drive pin (LDGA, LDGB, LDA0-4, and LDB0-4) has two states: Off and LOW. When none of the se- lected attributes are true, the driver is off and the diode is unlit. When an attribute is true, the driver is LOW, and the corresponding LEDs in Bank A or Bank B will be lit. Some of the settings (LDC2 = 1) include a blink func- tion. This allows two attributes to be selected for a given state on the pin. As an example when LDC0-2 = 110, the LDA outputs relating to TP ports will be solidly lit when there is a link established at that port. However, whenever there is activity on a port, the corresponding LDA pin will switch on (LOW) and off at a period of 130 ms. Note that a partition on that port will also cause the pin to go LOW. On LDC settings that have two attributes for a state on a pin (blink or solid-on), the attribute causing the output to blink has priority. (Those attributes are shown in Table 2 with a blink period specified next to it.) If an at- tribute has no blink period specified, the LED indicates the attribute by being solidly lit. The LEDs can also be controlled via the control port. The Enable Software Override commands turn the LEDs on regardless of the attributes selected for dis- play through the LDC setting. Enable Software Over- ride of Bank A LEDs causes the LDA0-4 and LDGA pins to be driven LOW, and Enable Software Override of Bank B LEDs causes the LDB0-4 and LDGB pins to be driven LOW. The blink rate is set by the Software Over- ride LED Blink Rate command. The periods are off, 512 ms, 1560 ms, or solid on. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |