| поискавой системы для электроныых деталей |
|
AM79C970A датащи(PDF) 54 Page - Advanced Micro Devices |
|
|
|||||||||||||||||||||||||||||
AM79C970A датащи(HTML) 54 Page - Advanced Micro Devices |
|
54 / 219 page ![]() AMD P R E L I M I N A R Y 54 Am79C970A Parity Error Response During every data phase of a DMA read operation, when the target indicates that the data is valid by asserting TRDY, the PCnet-PCI II controller samples the AD[31:0], C/ BE[3:0] and the PAR lines for a data parity error. When it detects a data parity error, the controller sets PERR (PCI Status register, bit 15) to ONE. When reporting of that error is enabled by setting PERREN (PCI Command register, bit 6) to ONE, the PCnet-PCI II controller also drives the PERR signal low and sets DATAPERR (PCI Status register, bit 8) to ONE. The assertion of PERR follows the corrupted data/byte en- ables by two clock cycles and PAR by one clock cycle. The figure below shows a transaction that has a parity error in the data phase. The PCnet-PCI II controller as- serts PERR on clock 8, two clock cycles after data is valid. The data on clock 5 is not checked for parity, since on a read access PAR is only required to be valid one clock after the target has asserted TRDY. The PCnet-PCI II controller then drives PERR high for one clock cycle, since PERR is a sustained tri-state signal. 19436A-26 FRAME CLK AD IRDY TRDY C/ BE DEVSEL PAR DEVSEL is sampled ADDR BE 0111 PAR 1 234 5 6 78 9 DATA PAR PERR Figure 23. Master Cycle Data Parity Error Response During every data phase of a DMA write operation, the PCnet-PCI II controller checks the PERR input to see if the target reports a parity error. When it sees the PERR input asserted, the controller sets PERR (PCI Status register, bit 15) to ONE. When PERREN (PCI Com- mand register, bit 6) is set to ONE, the PCnet-PCI II con- troller also sets DATAPERR (PCI Status register, bit 8) to ONE. Whenever the PCnet-PCI II controller is the current bus master and a data parity error occurs, SINT (CSR5, bit 11) will be set to ONE. When SINT is set, INTA is as- serted if the enable bit SINTE (CSR5, bit 10) is set to ONE. This mechanism can be used to inform the driver of the system error. The host can read the PCI Status register to determine the exact cause of the interrupt. The setting of SINT due to a data parity error is not de- pendent on the setting of PERREN (PCI Command register, bit 6). By default, a data parity error does not affect the state of the MAC engine. The PCnet-PCI II controller treats the data in all bus master transfers that have a parity |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |