| поискавой системы для электроныых деталей |
|
LMP7701 датащи(PDF) 21 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
LMP7701 датащи(HTML) 21 Page - Texas Instruments |
|
21 / 35 page ![]() SENSOR V + V - RS + - IB VIN+ VS + - 10 1k 100k 10M RS (:) 0.1 1 10 1000 1M 10k 100 100 eni en ei et LMP7701, LMP7702, LMP7704 www.ti.com SNOSAI9H – SEPTEMBER 2005 – REVISED MARCH 2013 Figure 52. Total Input Noise HIGH IMPEDANCE SENSOR INTERFACE Many sensors have high source impedances that may range up to 10 M Ω. The output signal of sensors often needs to be amplified or otherwise conditioned by means of an amplifier. The input bias current of this amplifier can load the sensor's output and cause a voltage drop across the source resistance as shown in Figure 53, where VIN + = V S – IBIAS*RS The last term, IBIAS*RS, shows the voltage drop across RS. To prevent errors introduced to the system due to this voltage, an op amp with very low input bias current must be used with high impedance sensors. This is to keep the error contribution by IBIAS*RS less than the input voltage noise of the amplifier, so that it will not become the dominant noise factor. Figure 53. Noise Due to IBIAS pH electrodes are very high impedance sensors. As their name indicates, they are used to measure the pH of a solution. They usually do this by generating an output voltage which is proportional to the pH of the solution. pH electrodes are calibrated so that they have zero output for a neutral solution, pH = 7, and positive and negative voltages for acidic or alkaline solutions. This means that the output of a pH electrode is bipolar and has to be level shifted to be used in a single supply system. The rate of change of this voltage is usually shown in mV/pH and is different for different pH sensors. Temperature is also an important factor in a pH electrode reading. The output voltage of the senor will change with temperature. Figure 54 shows a typical output voltage spectrum of a pH electrode. Note that the exact values of output voltage will be different for different sensors. In this example, the pH electrode has an output voltage of 59.15 mV/pH at 25°C. Copyright © 2005–2013, Texas Instruments Incorporated Submit Documentation Feedback 21 Product Folder Links: LMP7701 LMP7702 LMP7704 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |