| поискавой системы для электроныых деталей |
|
L9958 датащи(PDF) 20 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L9958 датащи(HTML) 20 Page - STMicroelectronics |
|
20 / 38 page ![]() Diagnostics and protections L9958 20/38 Doc ID 17269 Rev 5 5.2 Protection and on state diagnostics L9958 is protected against short circuits, overload and invalid supply voltage by the following measures. 5.2.1 Over-current on high-side - short to ground The high-side switches are protected against a short of the output to ground by an over- current shutdown. If a high-side switch is turned on and the current rises above the short circuit detection current Ioc all output transistors are turned off after a filter time Toc_ls and the error bits "overcurrent on high side 1 (2)", OC_HS1 (OC_HS2) are stored in the internal status register. 5.2.2 Over-current on low-side - short to Vs Due to the chopper current regulation, the low-side switches are already protected against a short to the supply voltage. To be able to distinguish a short circuit from normal current limit operation, the current limitation is deactivated for the blanking time tb after the current has exceeded the current limit threshold IH. If the short circuit detection current Ioc is reached within this blanking time, a short circuit is detected. All output transistors are turned OFF and the according error bit “Over-Current on Low Side 1 (2)”, OC_LS1 (OC_LS2) is set. 5.2.3 Short circuit over-load If, during the Blanking time (tb) of the current regulation mode, the current reaches the Ioc threshold; after a filtering time, the output MOS are switched OFF and the “Short circuit over load” can be checked by the reading of the overcurrent bits of the DIA_REG (please refer to Table 8 bit 8, 9,10 and 11). Figure 15. Diagnostics for SCB / SCOL 5.2.4 Open load in on state To perform the Open Load diagnosis in ON state, the flag OL_ON has to be set high through SPI. After every open load diagnosis in ON state, the OL_ON flag is resetted, to perform a new open load diagnosis in ON state the OL_ON flag has to be set again. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |