Back Button PCM1606E/2K Datasheet HTML 2Page - Texas Instruments PCM1606E/2K Datasheet HTML 3Page - Texas Instruments PCM1606E/2K Datasheet HTML 4Page - Texas Instruments PCM1606E/2K Datasheet HTML 5Page - Texas Instruments PCM1606E/2K Datasheet HTML 6Page - Texas Instruments PCM1606E/2K Datasheet HTML 7Page - Texas Instruments PCM1606E/2K Datasheet HTML 8Page - Texas Instruments PCM1606E/2K Datasheet HTML 9Page - Texas Instruments PCM1606E/2K Datasheet HTML 10Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 6 / 28 page
background image
PCM1606
SLES014B − OCTOBER 2001 − REVISED AUGUST 2002
6
www.ti.com
timing requirements (continued)
power-on reset functions
The PCM1606 includes a power-on reset function. Figure 2 shows the operation of this function. With the
system clock active and VCC > 3 V typical (2.2 V to 3.7 V), the power-on reset function is enabled. The
initialization sequence requires 1024 system clocks from the time VCC > 3 V. After the initialization period, the
PCM1606 is set to its reset default state.
Table 1. System Clock Rates for Common Audio Sampling Frequencies
SAMPLING FREQUENCY
SYSTEM CLOCK FREQUENCY (fSCLK) (MHz)
SAMPLING FREQUENCY
128 fS
192 fS
256 fS
384 fS
512 fS
768 fS
8 kHz
—
—
2.048
3.072
4.096
6.144
16 kHz
—
—
4.096
6.144
8.192
12.288
32 kHz
—
—
8.192
12.288
16.384
24.576
44.1 kHz
—
—
11.2896
16.9344
22.5792
33.8688
48 kHz
—
—
12.288
18.432
24.576
36.864
96 kHz
—
—
24.576
36.864
49.152
See Note 5
192 kHz
24.576
36.864
See Note 6
See Note 6
See Note 6
See Note 6
NOTES:
5. The 768-fS system clock rate is not supported for fS > 64 kHz.
6. This system clock is not supported for the given sampling frequency.
t(SCKH)
System Clock
Pulse Cycle Time†
System Clock
t(SCKL)
2.0 V
0.8 V
† 1/128 fS, 1/256 fS, 1/384 fS, 1/512 fS and 1/768 fS.
PARAMETERS
MIN
MAX
UNIT
t(SCKH)
System clock pulse duration HIGH
10
ns
t(SCKL)
System clock pulse duration LOW
10
ns
Figure 1. System Clock Timing
1024 System Clocks
System Clock
Internal Reset
3.7 V
3.0 V
2.2 V
VDD
0 V
Don’t Care
Reset
Reset Removal
Figure 2. Power-On Reset Timing



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28


датащи скачать

Go To PDF Page


ссылки URL



Вашему бизинису помогли Аллдатащит?  [ DONATE ] 

Что такое Аллдатащит   |   реклама   |   контакт   |   Конфиденциальность   |   Ссылка на техническое описание    |   обмен ссыками   |   поиск по производителю
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com