| поискавой системы для электроныых деталей |
|
PCM1606E/2K датащи(PDF) 5 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
PCM1606E/2K датащи(HTML) 5 Page - Texas Instruments |
|
5 / 28 page ![]() PCM1606 SLES014B − OCTOBER 2001 − REVISED AUGUST 2002 5 www.ti.com electrical characteristics, all specifications at TA = 25°C, VCC = 5 V, fS = 44.1 kHz, system clock = 384 fS and 24-bit data (unless otherwise noted) (continued) PARAMETER TEST CONDITIONS PCM1606E UNIT PARAMETER TEST CONDITIONS MIN TYP MAX UNIT DIGITAL FILTER PERFORMANCE FILTER CHARACTERISTICS Passband ±0.03 dB 0.454 fS Passband −3 dB 0.487 fS Stopband 0.546 fS Passband ripple ±0.03 dB Stopband attenuation Stopband = 0.546 fS −50 dB Stopband attenuation Stopband = 0.567 fS −55 dB ANALOG FILTER PERFORMANCE Frequency response At 20 kHz −0.03 dB POWER SUPPLY REQUIREMENTS (see Note 4) VCC Voltage range 4.5 5 5.5 VDC fS = 44.1 kHz/384 fS 50 65 ICC Supply current fS = 96 kHz/256 fS 72 mA ICC Supply current fS = 192 kHz/128 fS 68 mA fS = 44.1 kHz/384 fS 250 358 Power dissipation fS = 96 kHz/256 fS 360 mW Power dissipation fS = 192 kHz/128 fS 340 mW TEMPERATURE RANGE Operation temperature −25 85 °C θJA Thermal resistance 20-pin SSOP 115 °C/W NOTES: 3. Analog performance specs are tested using System Two Cascade Plus by Audio Precision with 400-Hz HPF, 30-kHz LPF on at RMS with 20-kHz LPF, 400-Hz HPF in calculation. Shibasoku #725 THD meter, 400 Hz HPF, 30 kHz LPF on, at average mode with 20-kHz bandwidth limiting. The load connected to the analog output is 5 k Ω or larger via capacitance coupling. 4. Condition in 192-kHz operation is channel 3 through channel 6 are disabled. timing requirements system clock input The PCM1606 requires a system clock for operating the digital interpolation filters and multilevel delta-sigma modulators. The system clock is applied at the SCKI (pin 20). Table 1 shows examples of system clock frequencies for common audio sampling rates. Figure 1 shows the timing requirements for the system clock input. For optimal performance, it is important to use a clock source with low phase jitter and noise. Texas Instruments’ PLL1700 multiclock generator is an excellent choice for providing the PCM1606 system clock source. The 192-kHz sampling frequency operation is available on DATA1 for VOUT1 and VOUT2. When the system clock of 128 fS or 192 fS is detected, VOUT3, VOUT4, VOUT5 and VOUT6 are automatically forced to the bipolar zero level (= 0.5 VCC). Table 1 lists the typical system clock frequency. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |