| поискавой системы для электроныых деталей |
|
AD9054 датащи(PDF) 12 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD9054 датащи(HTML) 12 Page - Analog Devices |
|
12 / 20 page ![]() AD9054 –12– REV. 0 When driven differentially, ENCODE and DS will accommo- date differential signals centered between 1.5 V and 4.5 V with a total differential swing ≥800 mV (V ID ≥ 400 mV). Note the 6-diode clock input protection circuitry in Figure 5. This limits the differential input voltage to ~ ±2.1 V. When the diodes turn on, current is limited by the 300 Ω series resistor. Exceeding 2.1 V across the differential inputs will have no im- pact on the performance of the converter, but be aware of the clock signal distortion that may be produced by the nonlinear impedance at the converter. CLOCK CLOCK ENC ENC VIH D VIC M VIL D CLOCK ENC ENC VIH D VIC M VIL D 0.1 F VID VID a. Driving Differential Inputs Differentially b. Driving Differential Inputs Single-Endedly Figure 34. Input Signal Level Definitions Single Port Mode When operated in a Single Port mode ( DEMUX = HIGH), the timing of the AD9054 is similar to any high speed A/D Con- verter (Figure 1). A sample is taken on every rising edge of ENCODE, and the resulting data is produced on the output pins following the FOURTH rising edge of ENCODE after the sample was taken (four pipeline delays). The output data are valid tPD after the rising edge of ENCODE, and remain valid until at least tV after the next rising edge of ENCODE. The maximum clock rate is specified as 100 MSPS. This is recommended because the guaranteed output data valid time equals the Clock Period (1/fS) minus the Output Propagation Delay (tPD) plus the Output Valid Time (tV), which comes to 4.8 ns at 100 MHz. This is about as fast as standard logic is able to capture the data with reasonable design margins. The AD9054 will operate faster in single-channel mode if you are able to capture the data. When operating in Single-Channel Mode, the outputs at Port B are held static in a random state. Figure 35 shows the AD9054 used in single-channel output mode. The analog input ( ±0.5 V) is ac coupled and the ENCODE input is driven by a TTL level signal. The chip’s internal refer- ence is used. VIN 0.1 F +5V 1k 0.1 F 0.1 F NC CLOCK VREF OUT VREF IN AIN AIN DEMUX AD9054 DS DS ENC ENC A PORT NC = NO CONNECT Figure 35. Single Port Mode—AC-Coupled Input—Single- Ended Encode Dual Port Mode In Dual Port Mode ( DEMUX = LOW), the conversion results are alternated between the two output ports (Figure 2). This limits the data output rate at either port to 1/2 the conversion rate (ENCODE), and supports conversion at up to 200 MSPS with TTL/CMOS compatible interfaces. Dual Channel Mode is required for guaranteed operation above 100 MSPS, but may be enabled at any specified conversion rate. The multiplexing is controlled internally via a clock divider, which introduces a degree of ambiguity in the port assignments. Figure 2 illustrates that, prior to synchronization, either Port A or Port B may produce the even or odd samples. This is re- solved by exercising the Data Sync (DS) control, a differential input (identical to the ENCODE input), which facilitates opera- tion at high speed. At least once after power-up, and prior to using the conversion data, the part needs to be synchronized by a falling edge (or a positive-going pulse) on DS (observing setup and hold times with respect to ENCODE). If the converter’s internal timing is in conflict with the DS signal when it is exercised, then two data samples (one on each port) are corrupted as the converter is resynchronized. The converter then produces data with a known phase relationship from that point forward. Note that if the converter is already properly synchronized, the DS pulse has no effect on the output data. This allows the con- verter to be continuously resynchronized by a pulse at 1/2 the ENCODE rate. This signal is often available within a system, as it represents the master clock rate for the demultiplexed output data. Of course, a single DS signal may be used to synchronize multiple A/D converters in a multichannel system. Applications that call for the AD9054 to be synchronized at power-up or only periodically during calibration/reset (i.e., valid data is not required prior to synchronization), need only be concerned with the timing of the falling edge of DS. The falling edge of DS must satisfy the setup time defined by Figure 2 and |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |