| поискавой системы для электроныых деталей |
|
AD7707 датащи(PDF) 31 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD7707 датащи(HTML) 31 Page - Analog Devices |
|
31 / 40 page ![]() REV. A AD7707 –31– AD7707 to 8051 Interface An interface circuit between the AD7707 and the 8XC51 microcontroller is shown in Figure 22. The diagram shows the minimum number of interface connections with CS on the AD7707 hard-wired low. In the case of the 8XC51 interface the minimum number of interconnects is just two. In this scheme, the DRDY bit of the Communications Register is monitored to determine when the Data Register is updated. The alternative scheme, which increases the number of interface lines to three, is to monitor the DRDY output line from the AD7707. The monitoring of the DRDY line can be done in two ways. First, DRDY can be connected to one of the 8XC51’s port bits (such as P1.0) which is configured as an input. This port bit is then polled to determine the status of DRDY. The second scheme is to use an interrupt-driven system, in which case the DRDY output is connected to the INT1 input of the 8XC51. For inter- faces that require control of the CS input on the AD7707, one of the port bits of the 8XC51 (such as P1.1), which is config- ured as an output, can be used to drive the CS input. The 8XC51 is configured in its Mode 0 serial interface mode. Its serial interface contains a single data line. As a result, the DATA OUT and DATA IN pins of the AD7707 should be connected together with a 10 k Ω pull-up resistor. The serial clock on the 8XC51 idles high between data transfers. The 8XC51 outputs the LSB first in a write operation, while the AD7707 expects the MSB first so the data to be transmitted has to be rearranged before being written to the output serial regis- ter. Similarly, the AD7707 outputs the MSB first during a read operation while the 8XC51 expects the LSB first. Therefore, the data read into the serial buffer needs to be rearranged before the correct data word from the AD7707 is available in the accumulator. RFS DT ADSP-2103/ ADSP-2105 RESET SCLK DATA OUT DATA IN CS AD7707 VDD TFS DR SCLK Figure 23. AD7707 to ADSP-2103/ADSP-2105 Interface AD7707 to ADSP-2103/ADSP-2105 Interface Figure 23 shows an interface between the AD7707 and the ADSP-2103/ADSP-2105 DSP processor. In the interface shown, the DRDY bit of the Communications Register is again monitored to determine when the Data Register is updated. The alternative scheme is to use an interrupt-driven system, in which case the DRDY output is connected to the IRQ2 input of the ADSP-2103/ADSP-2105. The serial interface of the ADSP- 2103/ADSP-2105 is set up for alternate framing mode. The RFS and TFS pins of the ADSP-2103/ADSP-2105 are config- ured as active low outputs and the ADSP-2103/ADSP-2105 serial clock line, SCLK, is also configured as an output. The CS for the AD7707 is active when either the RFS or TFS outputs from the ADSP-2103/ADSP-2105 are active. The serial clock rate on the ADSP-2103/ADSP-2105 should be limited to 3 MHz to ensure correct operation with the AD7707. CODE FOR SETTING UP THE AD7707 Table XVII gives a set of read and write routines in C code for interfacing the 68HC11 microcontroller to the AD7707. The sample program sets up the various registers on the AD7707 and reads 1000 samples from the part into the 68HC11. The setup conditions on the part are exactly the same as those out- lined for the flowchart of Figure 20. In the example code given here, the DRDY output is polled to determine if a new valid word is available in the data register. The sequence of the events in this program are as follows: 1. Write to the Communications Register, selecting channel one as the active channel and setting the next operation to be a write to the clock register. 2. Write to Clock Register setting the CLK DIV bit which divides the external clock internally by two. This assumes that the external crystal is 4.9512 MHz. The update rate is selected to be 50 Hz. 3. Write to Communication Register selecting Channel 1 as the active channel and setting the next operation to be a write to the Setup Register. 4. Write to the Setup Register, setting the gain to 1, setting bipolar mode, buffer off, clearing the filter synchronization and initiating a self-calibration. 5. Poll the DRDY output. 6. Read the data from the Data Register. 7. Loop around doing Steps 5 and 6 until the specified number of samples have been taken from the selected channel. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |