20 / 32 page ![]() 50-604 Kotron Model 804 Sentinel II RF Level Transmitter 17 2.5.8 I/O Configuration Menu (cont.) The I/O Configuration menu is used to configure the discrete relay output, 4–20 mA output, and communication parameters of the Sentinel II. The menu is divided into two tables: Discrete output settings; and 4–20 mA/communications settings. 2.5.8.2 Setting 4–20 mA and communications output Following is a step-by-step procedure for setting the 4–20 mA and communications output. It is assumed that you are beginning at the RUN mode. Current Menu Location Display Action Comments Run Magnetrol Int’l x.x level units Normal operation This is the RUN mode. Run/I/O CONFIG I/O Config > to select Access the I/O Config menu Press the down arrow until the display reads I/O Config. Run/I/O Config/ 4–20 mA Settings 4–20 mA Settings > to select Access the 4–20 mA Settings menu Run/I/O Config/ 4–20 mA Settings Enable/Disable Disable Activate the 4–20 mA Output menu Select to use (enable) or bypass (disable) the 4–20 mA output. Run/I/O Config/ 4–20 mA Settings 4 mA Point x.xx in Set the 4 mA level Enter the level of the desired 4 mA output. Run/I/O Config/ 4–20 mA Settings 20 mA Point x.xx in Set the 20 mA level Enter the level of the desired 20 mA output. Run/I/O Config/ 4–20 mA Settings Fault Mode off Set the output state on fault Select the state of the 4–20 mA Output in the event of a unit fault. Use the arrow keys to select the fault option (3.5 mA, 22 mA, or HOLD). Run/I/O Config/ 4–20 mA Settings Previous Menu x.xx in Press ENT. Run/I/O Config/Comm Port Setup Comm Port Setup > to select Access the Comm Port Setup menu Set a specific address for this device when used with a digital communications protocol. Run/I/O Config/ Comm Port Settings Address (0–256) > to select Set the unit’s communication 0 This is the I.D. byte used to select this particular unit during polling. Run/I/O Config/ Comm Port Settings Baud rate 9600 Set the unit’s communication speed The selection options are 300, 1200, 4800, 9600. Run/I/O Config/ Comm Port Settings Parity Odd Set the condition of the parity bit The selection options are Odd, Even, or None. Run/I/O Config/ Comm Port Settings Previous Menu > to select Press ENT. Press DEL twice to return to the RUN mode. Run Magnetrol Int’l x.x level units Normal operation The RUN mode. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |