19 / 32 page ![]() 50-604 Kotron Model 804 Sentinel II RF Level Transmitter 16 2.5.8 I/O Configuration Menu The I/O Configuration menu is used to configure the discrete relay output, 4–20 mA output, and communication parameters of the Sentinel II. The menu is divided into two tables: Discrete output settings; and 4–20 mA/communications settings. 2.5.8.1 Discrete output settings Follow the step-by-step procedure for setting the discrete output. It is assumed that you are starting from the RUN mode. Current Menu Location Display Action Comments Run Magnetrol Int’l x.x level units Normal operation This is the RUN mode. Run/I/O CONFIG I/O Config > to select Access the I/O Config menu Use the arrow keys to scroll down until the display reads I/O Config. Run/I/O Config/ Relay Settings Relay Settings > to select Access the Relay Settings menu This menu allows you to set all discrete output parameters (Relay). Run/I/O Config/ Relay Settings Select Relay > to select Select the relay to configure This menu allows you to set specific parameters concerning individual set points. Enter the discrete output number (1–4). NOTE: If you enabled Relay #1 as the fault relay, control output options are (2–4). Run/I/O Config/ Relay Settings Select Relay Fault Relay (#1) Disable Select relay #1 as the fault relay This display will only appear if Relay #1 is selected in the preceding step. Select Relay #1 as the fault relay (enable) or as a standard discrete output (disable) Run/I/O Config/ Relay Settings Select Relay Enable/disable disable Activate the relay Select to use (enable) or bypass (disable) this output. Run/I/O Config/ Relay Settings Select Relay Relay On point X.XX in Set the relay energize point Enter the level at which you want the output to energize. Run/I/O Config/ Relay Settings Select Relay Relay Off point X.XX in Set the relay de-energize point Enter the level at which you want the output to de-energize. Run/I/O Config/ Relay Settings Select Relay Fail-safe DNRG>Set point Select the fail-safe condition This step will only appear if the Relay On and Relay Off points are the same. Select either DNRG<Set point (low level fail-safe) or DNRG>Set point (high level fail-safe). Run/I/O Config/ Relay Settings Select Relay Relay On Delay 1 sec Set the relay energize delay Enter the desired delay period before the relay energizes. Run/I/O Config/ Relay Settings Select Relay Relay Off Delay 1 sec Set the relay de-energize delay Enter the desired delay period before the relay de-energizes. Run/I/O Config/ Relay Settings Select Relay Fault Mode DNRG on fault Select the output state on fault Select whether the control output will de-energize on a system fault or hold the latest output. Run/I/O Config/ Relay Settings Previous Menu > to select Run/I/O Config/ Relay Settings Select Relay > to select Run/I/O Config/ Relay Settings Lead Lag Mode Lead Lag Mode DNRG>Set point Set the Lead/Lag relay combinations This menu allows you to select various options concerning multiple pump sequencing. Use the arrow keys to select the various pump sequencing options (1-2, 1-2-3, 1-2-3-4, etc.). If relay #1 was selected as the fault relay, options containing 1 will not be available. Run/I/O Config/ Relay Settings Previous Menu > to select Run/I/O Config/ Relay Settings Relay Settings > to select Press the down arrow to setup the 4–20 mA output or communications options (the next table) or press DEL two times to return to the RUN mode. Run Magnetrol Int’l x.x level units Normal operation The RUN mode. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |