84 / 166 page ![]() 84 of 166 VSC060 Data Sheet Revision 4.1 January 2008 3.2.87 6Dh: Fan Speed Count Overflow 15 (FSCO15) The following table shows the bit assignments for the Fan Speed Count Overflow 15 register. This register functions same the Fan Speed Count Overflow 0 register except it affects the P2.7 pin. 3.2.88 6Eh: Fan Speed Current Count 15 (FSCC15) The following table shows the bit assignments for the Fan Speed Current Count 15 register. This register functions the same as Fan Speed Current Count 0 except it affects the P2.7 pin. Register Name: FSCO15 Address: 6Dh Reset Value: 0000_0000b Bit Bit Label Access Description 7:0 FSCO7-0 R/W Fan Speed Count Overflow These eight bits are compared to the 8-bit fan speed counter. If the counter exceeds this value, an interrupt is generated. This register should be loaded prior to setting the FSCEN bit in the FSC15 register to avoid generating unintentional interrupts. The overflow count value can be determined using the following equation, where FF% is equal to the percentage of nominal RPM that constitutes a fan failure: Decimal overflow count value = (1,200,000) / (RPM × divisor × FF%) Based on the above equation, a divisor of 8, and a detected fan failure at 70% of nominal RPM, the fan speed monitoring logic can support a low-end nominal RPM of 850. High-end RPM values are basically unlimited; however, counter resolution is diminished above 8000 RPM. Register Name: FSCC15 Address: 6Eh Reset Value: 0000_0000b Bit Bit Label Access Description 7:0 FSCC7-0 R These eight bits, when enabled by setting the FSCEN bit in the FSC15 register, provide the user with an accurate binary fan speed count value that can be used to determine the current RPM value of the fan. A minimum of one complete revolution of the fan is required to generate an accurate fan speed count value. The following equation can be used to determine the current RPM value of the fan: RPM = (1,200,000) / (Decimal count value × divisor) When the result of a read of this register is 00h, an accurate fan speed count value is not generated, indicating that the fan has not completed a minimum of one revolution. When the result of a read of this register is FFh, the fan is rotating very slowly or no tachometer pulses are present. When operating in a polled mode, with the FSIEN bit reset in the FSC15 register, this register is automatically updated with an accurate fan speed count once per revolution of the fan. When operating in an Interrupt mode with the FSIEN bit set in the FSC15 register, this register is automatically updated with an accurate fan speed count, once per revolution of the fan, until an interrupt is generated. After the interrupt is generated, the value remains stable until the interrupt is cleared. When the interrupt is cleared, this register is also cleared, indicating that a valid RPM value is in the process of being generated. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |