| поискавой системы для электроныых деталей |
|
ADT7483AARQZ-R7 датащи(PDF) 11 Page - ON Semiconductor |
|
|
|||||||||||||||||||||||||||||
ADT7483AARQZ-R7 датащи(HTML) 11 Page - ON Semiconductor |
|
11 / 24 page ![]() ADT7483A Rev. 1 | Page 11 of 24 | www.onsemi.com Table 7. Temperature Data Format (Local and Remote Temperature High Byte) Temperature Binary Offset Binary1 –55°C 0 000 00002 0 000 1001 0°C 0 000 0000 0 100 0000 +1°C 0 000 0001 0 100 0001 +10°C 0 000 1010 0 100 1010 +25°C 0 001 1001 0 101 1001 +50°C 0 011 0010 0 111 0010 +75°C 0 100 1011 1 000 1011 +100°C 0 110 0100 1 010 0100 +125°C 0 111 1101 1 011 1101 +127°C 0 111 1111 1 011 1111 +150°C 0 111 11113 1 101 0110 1 Offset binary scale temperature values are offset by +64. 2 Binary scale temperature measurement returns 0 for all temperatures <0°C. 3 Binary scale temperature measurement returns 127 for all temperatures >127°C. The user may switch between measurement ranges at any time. Switching the range also switches the data format. The next temperature result following the switching is reported back to the register in the new format. However, the contents of the limit registers do not change. It is up to the user to ensure that when the data format changes, the limit registers are reprogrammed as necessary (for more information, see the Limit Registers section). REGISTERS The registers in the ADT7483A are eight bits wide. These registers are used to store the results of remote and local temperature measurements, and high and low temperature limits, and to configure and control the device. A description of these registers is provided in this section. Address Pointer Register The address pointer register does not have, nor does it require, an address because the first byte of every write operation is automatically written to this register. The data in this first byte always contains the address of another register on the ADT7483A, which is stored in the address pointer register. It is to this other register address that the second byte of a write operation is written, or to which a subsequent read operation is performed. The power-on default value of the address pointer register is 0x00, so if a read operation is performed immediately after power-on without first writing to the address pointer, the value of the local temperature will be returned, since its register address is 0x00. Temperature Value Registers The ADT7483A has five registers to store the results of local and remote temperature measurements. These registers can only be written to by the ADC and can be read by the user over the SMBus. • The local temperature value register is at Address 0x00. • The Remote 1 temperature value high byte register is at Address 0x01, with the Remote 1 low byte register at Address 0x10. • The Remote 2 temperature value high byte register is at Address 0x30, with the Remote 2 low byte register at Address 0x33. • The Remote 2 temperature values can be read from Address 0x01 for the high byte and Address 0x10 for the low byte if Bit 3 of Configuration Register 1 is set to 1. • To read the Remote 1 temperature values, Bit 3 of Configuration Register 1 should be set to 0. • The power-on default for all five registers is 0x00. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |