| поискавой системы для электроныых деталей |
|
SS7646 датащи(PDF) 8 Page - Silicon Standard Corp. |
|
|
|||||||||||||||||||||||||||||
SS7646 датащи(HTML) 8 Page - Silicon Standard Corp. |
|
8 / 13 page ![]() www.SiliconStandard.com 4 of 5 SS7646 8/21/2004 Rev.2.01 A2A1A0 (S ho w n 101 ) Y- X+ Y+ X- V BAT V IN VDD B attery M o nito r /PEN IR Q ADC + R E F -R E F IN V R EF M O D E 0 (S ho w n 1) V DD Figure 5. Diagram of Input Channel and Reference Input ANALOG INPUT MEASUREMENT The SS7646 contains 6 channel inputs. X+, Y+ and Y- inputs are for touch screen measurement, 2 auxiliary inputs are VBAT and VIN. The diode input (internal node) is for temperature measurement. Figure 5 shows a diagram of the analog input channel and reference input. The input to the A/D converter is selected via the s i x - c hannel m u ltiple x e r . ( s ee Blo c k Diagram and Figure 5.) Input Channel Table III shown the input channel configuration of the SS7646. The control bits are set via the DIN pin. (see Control Byte section). The selected channel is for A/D converter input. Please refer to Figure 5 for detailed input channel multiplexer. For measuring X+ (Y-position) and Y+ (X-position), Y switches and X switches are turned on respectively. Internal Reference The SS7646 has an internal 2.5V voltage reference that can be turned ON with the power-down address bit, PD1=”1”, at the configuration byte (See Table V and Figure 1). The internal reference voltage of SS7646 should be turned OFF (PD1=”0”) in order to be compatible with the SS7643. If the internal reference is turned OFF and the reference is taken from the power supply directly, special care must be taken to avoid noise from the power supply. While the ADC can be powered up or down instantly, the internal reference requires settling time to settle to the final value. The power-up time of VREF is typically 30 µs without a load. The internal reference voltage can be turned ON or OFF independently of the ADC. T his allows extra time for the reference voltage to be settled before a conversion. Although /CS=”1” will put the SS7646 into a power-down mode immediately, the internal reference does not turn OFF with /CS going HIGH. An additional pattern with PD1=”0” is required before /CS goes HIGH. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |