| поискавой системы для электроныых деталей |
|
DS1876 датащи(PDF) 45 Page - Maxim Integrated Products |
|
|
|||||||||||||||||||||||||||||
DS1876 датащи(HTML) 45 Page - Maxim Integrated Products |
|
45 / 69 page ![]() ______________________________________________________________________________________ 45 SFP Controller with Dual LDD Interface Table 02h, Register 80h: MODE (continued) Table 02h, Register 81h: TEMPERATURE INDEX (TINDEX) BIT 2 MOD1EN: 0 = MOD1 DAC is writable by the user and the LUT recalls are disabled. This allows the user to interactively test their modules by writing the values for MOD1. The output is updated with the new value at the end of the write cycle. The I2C STOP condition is the end of the write cycle. 1 = (default) Enables automatic control of the LUT for MOD1 DAC. BIT 1 QT1EN: 0 = QTs (HBIAS, TXP HI, TXP LO) for transmitter 1 are writable by the user and the LUT recalls are disabled. This allows the user to interactively test their modules by writing to the QT thresholds. The thresholds are updated with the new values at the end of the write cycle. The I2C STOP condition is the end of the write cycle. 1 = (default) Enables automatic control of the LUT QTs for transmitter 1. BIT 0 APC1EN: 0 = APC1 DAC is writable by the user and the LUT recalls are disabled. This allows the user to interactively test their modules by writing the values for APC1. The output is updated with the new value at the end of the write cycle. The I2C STOP condition is the end of the write cycle. 1 = (default) Enables automatic control of the LUT for APC1 DAC. FACTORY DEFAULT 00h READ ACCESS PW2 or (PW1 and RWTBL2) or (PW1 and RTBL2) WRITE ACCESS (PW2 and AEN = 0) or (PW1 and RWTBL2 and AEN = 0) A2h AND B2h MEMORY Common A2h and B2h memory location MEMORY TYPE Volatile 81h 27 26 25 24 23 22 21 20 BIT 7 BIT 0 Holds the calculated index based on the temperature measurement. This index is used for the address during lookup of Tables 04h and 06h. Temperature measurements below -40NC or above +102NC are clamped to 80h and C7h, respectively. The calculation of TINDEX is as follows: Temp_Value 40 C TINDEX 80h 2 C + ° = + ° For the temperature-indexed LUTs (2NC), the index used during the lookup function for each table is as follows: Table 04h (MOD) 1 TINDEX6 TINDEX5 TINDEX4 TINDEX3 TINDEX2 TINDEX1 TINDEX0 Table 06h (APC) 1 TINDEX6 TINDEX5 TINDEX4 TINDEX3 TINDEX2 TINDEX1 TINDEX0 For the 8-position LUT tables, the following table shows the lookup function: TINDEX 1000_0xxx 1001_0xxx 1001_1xxx 1010_0xxx 1010_1xxx 1011_0xxx 1011_1xxx 11xx_xxxx BYTE F8 F9 FA FB FC FD FE FF TEMP (NC) < -8 -8 to +8 +8 to +24 +24 to +40 +40 to +56 +56 to +72 +72 to +88 R 88 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |