AS8118 датащи(PDF) 14 Page - ams AG |
|
|
|||||||||||||||||||||||||||||
AS8118 датащи(HTML) 14 Page - ams AG |
|
14 / 30 page ![]() Data Sheet AS8118 Revision 1.8, 15-Feb-05 Page 14 of 30 Parameter Description Number of bits Register bits Settings Default F_led_sel Select LED pulse rate [imp/kWh] 3 [26:24] [59:57] 000 : 100 001 : 200 010 : 400 011 : 800 100 : 1600 101 : 3200 110 : 6400 101 Pulse_lev Central pulse_level value 22 [23:2] [56:35] 0x6A6D4 Bank01 Select PROM bank 0 or 1 1[1] 0 : Bank 0 1 : Bank 1 0 Sel_def Select default or programmed values 1[0] 0 : default 1 : programmed Value 0 Not used 2 [69:68] 00 Total 70 The “Default” values are hard coded on-chip outside the PROM block. Only once the Sel_def bit has been set, are the PROM parameters selected by the AS8118. Two PROM banks are defined as ‘Bank 0’ and ‘Bank 1’. This feature allows for a complete reprogramming cycle if necessary. The required bank is selected with the bit called Bank01. The calibration of the AS8118 adjusts the specific pulse-level (Pulse_lev), which defines exactly the energy level when a pulse has to be generated and presented to the output. This pulse-level is used to define a very fast internal pulse rate from which the external pulse outputs are derived. Therefore, the AS8118 is extremely flexible in defining pulse output rates as required for a specified kWh meter. The parameters F_mon_sel, F_cal_sel and F_led_sel are used to define the pulse rates for the pins MOP/MON, CAL and LED. The Acreep_sel bit defines the threshold for the current for when no pulses should be transmitted. Calculations for Calibration This paragraph describes how to successfully calibrate the AS8118 device. The parameter Pulse_lev is the main parameter to determine the basic internal (very fast) frequency. This frequency relates to the measured power and is the basis from which all the output pulse rates namely, MOP/MON, CAL and LED are derived. Prior to system calibration, the appropriate value for the parameter Pulse_lev must be calculated to produce the required output pulse rates for MOP/MON, CAL and LED. The calibration exercise must accommodate all system non-idealities that are present in the meter system. There are two calibration methods available to find the appropriate value of Pulse_lev, namely: - Defined current and calibration time method - Comparison method It is also possible to perform: - Calibration without on-chip programming |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |