7 / 30 page ![]() Data Sheet AS8118 Revision 1.8, 15-Feb-05 Page 7 of 30 Digital Filters The current and voltage channels have been identically implemented with digital high pass filters in both channels, thus eliminating offsets. The filters ensure that there are no phase errors introduced between the voltage and current channels, enabling single point calibration. Energy to Pulse Output Conversion The energy value is accumulated in the energy accumulator and compared with the default or programmed threshold level, following each sample. The threshold represents the pulse equivalent energy value. If the energy value goes above the threshold, a pulse is generated and presented to the output. Each time a pulse is generated the threshold value is subtracted from the contents of the energy accumulator. The remaining energy, namely the energy value above the threshold value is retained in the accumulator. Further measured energy is added to the retained value in the accumulator and a pulse is again generated and presented to the output, when the value again exceeds the threshold value. Thus no energy is lost during the energy to pulse output conversion process. The voltage and current signals are sampled at 1.7478kHz. The sample rate is derived from the main clock (FMCLK) as follows: 3.57945 MHz / 8*256 = 1.7478 kHz The number of measured harmonics is defined by the sample rates of the voltage and current input signals. The maximum bandwidth, which is half the sample frequency, is calculated as follows: 1.7478/2 kHz = 873.9 Hz Thus, depending on the mains frequency, the measured energy is up to the following harmonics: 50Hz mains = 17th harmonic 60Hz mains = 14th harmonic Energy Pulse Outputs The AS8118 has three different pulse outputs. All the outputs are derived directly from the measured energy; thus, the outputs can be used for energy accumulation and for calibration purposes. The output options include the following: - CAL: A higher pulse rate output for fast calibration - MOP/MON: Low pulse rate outputs for directly driving a stepper motor - LED: A low pulse rate output which may be used to directly drive a LED for displaying power consumption Calibration Pulse Output (CAL): The CAL output is a high frequency output, the frequency of which is proportional to the real power measured. The output pulse rate is programmable via the on-chip memory and allows for 4 pulse rate options: Parameter: F_cal_sel Setting CAL Output Pulse Rate 00 MON/MOP x 8 01 MON/MOP x 16 10 MON/MOP x 32 11 MON/MOP x 64 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |