71 / 101 page ![]() Low-Power, Multifunction, Polyphase AFE ______________________________________________________________________________________ 71 The order of the harmonic is set in ORDH field of the AUX_CFG register. Also in the AUX_CFG register are two bits that enable the auxiliary channel and enable harmonic measure- ment on the auxiliary channel. To enable the auxiliary channel, set the ENAUX bit. Once set, the MAXQ3180 will perform an RMS calculation on the selected chan- nel. This is useful only for the IN (neutral current) chan- nel, since every other voltage and current already have RMS calculations applied by default. (The DADCNV bit should be cleared in the SCAN_IN register in order to enable sampling the IN channel.) To enable harmonic measurement, set the ENHARM bit. Now, the selected voltage or current signal is passed to a filter that is identical to the second-order fundamental filter, but that has separate parameters (A1HARM, B0HARM). Low-Power Measurement Mode (LOWPM) This mode enables a subset of metering functions while operating from the lower frequency internal RC oscilla- tor to conserve power. The actual system clock fre- quency used is the RC oscillator output frequency divided by 8, which results in a system clock frequency of approximately 1MHz. The parameters provided in the LOWPM are: • Voltage RMS • Current RMS • Ampere-Hour The ampere-hour value is readable from the X.ESF reg- isters (X = A/B/C). Entry to LOWPM mode only occurs at the request of the master. The master must set the LOWPM_E bit (register address 0xC03) to 1 to place the MAXQ3180 into LOWPM mode. Entering LOWPM mode changes the clock frequency, thereby invalidat- ing a number of configuration registers. As a result, the master must immediately reload the configuration regis- ters and filter with new, updated values before metering measurement operations can continue. The master instructs the MAXQ3180 to exit LOWPM mode by reading the LOWPM_X bit (register address 0xC04). Temperature The MAXQ3180 contains a temperature sensor that can be used by host software for any purpose, including compensating power readings for temperature effects. Use the virtual register command (RAWTEMP, 0xC01) to perform a temperature conversion. The MAXQ3180 returns raw ADC reading of voltage produced by the temperature sensor. Conversion from the arbitrary units to useful units (such as degrees Celsius) requires taking one calibration point and storing a conversion constant in the host processor. The conversion constant is simply the value (in absolute degrees) of one LSB. To calculate the LSB value, take a reading at a known temperature and divide the known temperature by the reading. For example, assume you take a reading at room temperature (23°C), and the reading is 0x7F00. The degrees per LSB are then: (23 + 273.15)/0x7F00 = 0.00911K Now, assume at a later time you read the temperature and see it is 0x84F0. To find the temperature in Celsius, multiply by the degrees per LSB and subtract 273.15: 0x84F0 x 0.00911 - 273.15 = 36.8 °C Advanced Calibrations Calibrating Current Offset Ideal hardware should produce a current reading lin- early proportional to the input current. However, due to noise or other factors, the RMS current read by the meter might not be precisely linear. The current offset (X.OFFS_HI, X = A/B/C) can be used to compensate the current channel nonlinearity. Since the MAXQ3180 tracks the input current to deter- mine what linearity compensation factors to use, the user must choose two points (ilo and ihi) comfortably above the low current threshold, and get the X.IRMS current readings (rlo and rhi). Then calculate the Y-inter- cept of the line drawn between the two points, that is, the offset. To calculate the value for the offset register, use the following formula. If LINFRM = 0: If LINFRM = 1: In this equation, ihi and rhi are the applied current and the current reading, respectively, in meter units at the higher of the two reference currents; ilo and rlo are the applied current and the current reading, respectively, in meter units at the lower of the two reference currents. The gain (X.I_GAIN) may require recalibration after the offset register updated. offs ri i r ii hi lo hi lo lo hi = − − () 2 4 offs ri i r ii hi lo hi lo hi lo = − − 22 2 2 24 2 2 2( ) |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |