| поискавой системы для электроныых деталей |
|
TLE8262E датащи(PDF) 13 Page - Infineon Technologies AG |
|
|
|||||||||||||||||||||||||||||
TLE8262E датащи(HTML) 13 Page - Infineon Technologies AG |
|
13 / 93 page ![]() Data Sheet 13 Rev. 1.0, 2009-03-31 TLE8262E State Machine 4.2.7 SBC Software Flash Mode SBC Software Flash Mode is similar to SBC Normal Mode regarding voltage regulators. In this mode, the Limp Home output can be set to active LOW via SPI and the communication on CAN and LIN modules is activated to receive flash data. In the LIN module the slope control mechanism is switched off. The Watchdog configuration is fixed to the settings used before entering the SBC SW Flash Mode. When the device comes from SBC Normal Mode, a reset is generated at the transition. From the SBC Software Flash Mode, the SBC goes into SBC Restart Mode, the config setting has no influence on the behavior. A mode change to SBC Restart Mode can be caused by a SPI command, a time-out or Window Watchdog failure or an undervoltage reset. When leaving the SBC Software Flash Mode a reset is generated. 4.2.8 SBC Restart Mode They are multiple reasons to enter the SBC Restart Mode and multiple SBC behaviors described in Table 2. In any case, the purpose of the SBC Restart Mode is to reset the microcontroller. • From SBC SW Flash Mode, it is used to start the new downloaded code. • From SBC Normal, SBC Stop Mode and SBC SW Flash Mode it is reached in case of undervoltage on V cc1µC, or due to incorrect Watchdog triggering. • From SBC Sleep Mode it is used to ramp up V cc1µC after wake • From SBC Init Mode, it is used to avoid the system to remain undefined. • From SBC Fail-safe Mode it is used to ramp up V cc1µC after wake or cool down of Vcc1µC. From SBC Restart Mode, the SBC goes automatically to SBC Normal Mode. The delay time tRDx is programmable by the “Reset delay” SPI bit. The Reset output (RO) is released at the transition. SBC Restart Mode is left automatically by the SBC without any microcontroller influence. The first SPI output data will provide information about the reason for entering Restart Mode. The reason for entering Restart Mode is stored and kept until the microcontroller reads the corresponding “LH0..2” or “RM0..1” SPI bits. In case of a wake up from Sleep Mode the wake source is seen at the interrupt bits (Configuration select 000), an interrupt is not generated. Entering or leaving the SBC Restart Mode will not result in deactivation of the Limp Home output (if activated). The first SPI output data when going to SBC Normal Mode will always indicate the reason for the SBC Restart event. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |