| поискавой системы для электроныых деталей |
|
SH7750 датащи(PDF) 13 Page - Renesas Technology Corp |
|
|
|||||||||||||||||||||||||||||
SH7750 датащи(HTML) 13 Page - Renesas Technology Corp |
|
13 / 1162 page ![]() Rev.7.00 Oct. 10, 2008 Page xiii of lxxxiv REJ09B0366-0700 Item Page Revision (See Manual for Details) 5.7 Usage Notes 182 Description amended 2. If a general exception or interrupt occurs when SR.BL = 1 a. General exception When a general exception other than a user break occurs, a manual reset is executed. The value in EXPEVT at this time is H'0000 0020; the value of the SPC and SSR registers is undefined. ... 3. SPC when an exception occurs a. Re-execution type general exception The PC value for the instruction in which the general exception occurred is set in SPC, and the instruction is re- executed after returning from exception handling. If an exception occurs in a delay slot instruction, however, the PC value for the delay slot instruction is saved in SPC regardless of whether or not the preceding delayed branch instruction condition is satisfied. b. Completion type general exception or interrupt The PC value for the instruction following that in which the general exception occurred is set in SPC. If an exception occurs in a branch instruction with delay slot, however, the PC value for the branch destination is saved in SPC. 6.5 Floating-Point Exceptions • Enable/disable exception handling 194 Description amended For information on these possibilities, see the individual instruction descriptions in chapter 9 of the SH-4 Software Manual. The particulars differ demanding on the instruction. All exception events that originate in the FPU are assigned as the same exception event. The meaning of an exception is determined by software by reading system register FPSCR and interpreting the information it contains. 6.6.2 Pair Single- Precision Data Transfer 196 Description amended In addition to the geometric operation instructions, the FPU also supports high-speed data transfer instructions. When FPSCR.SZ = 1, the FPU can perform data transfer by means of pair single-precision data transfer instructions. 6.7 Usage Notes 197 to 207 Newly added |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |