| поискавой системы для электроныых деталей |
|
33911 датащи(PDF) 28 Page - Freescale Semiconductor, Inc |
|
|
|||||||||||||||||||||||||||||
33911 датащи(HTML) 28 Page - Freescale Semiconductor, Inc |
|
28 / 45 page ![]() Analog Integrated Circuit Device Data 28 Freescale Semiconductor 33911 FUNCTIONAL DEVICE OPERATIONS OPERATIONAL MODES Figure 17. High Side Driver HS1 Open Load Detection The high side driver signals an open-load condition if the current through the high side is below the open-load current threshold. The open-load condition is indicated with the HS1OP bits in the High Side Status Register (HSSR). Current Limitation The high side driver has an output current limitation. In combination with the over-temperature shutdown, the high side driver is protected against over-current and short-circuit failures. When the driver operates in the current limitation area, it is indicated with the bit HS1CL in the HSSR. Note: If the driver is operating in current limitation mode excessive power might be dissipated. Over-temperature Protection (HS Interrupt) The high side driver is protected against over-temperature. In case of an over-temperature condition, the high side driver is shut down and the event is latched in the Interrupt Control Module. The shutdown is indicated as an HS Interrupt in the Interrupt Source Register (ISR). A thermal shutdown of the high side driver is indicated by setting the HS1OP and HS1CL bits simultaneously. If the bit HSM is set in the Interrupt Mask Register (IMR) than an interrupt (IRQ) is generated. A write to the High Side Control Register (HSCR), when the over-temperature condition is gone, will re-enable the high side driver. High-voltage Shutdown In case of a high-voltage condition, and if the high-voltage shutdown is enabled (bit HVSE in the Mode Control Register (MCR) is set), the high side driver is shut down. A write to the HSCR, when the high-voltage condition is gone, will re-enable the high side driver. Sleep And Stop Mode The high side driver can be enabled to operate in Sleep and Stop Mode for cyclic sensing. Also see Table 5, Operating Modes Overview. High Side - Driver charge pump open load detection current limitation overtemperture shutdown (interrupt maskable) high voltage shutdown (maskable) Control on/off Status PWMIN VDD PWMHS1 HS1 HVSE HS1OP HS1CL MOD1:2 Interrupt Control Module HS1 VS2 VDD Wakeup Module |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |