| поискавой системы для электроныых деталей |
|
CC2430DB датащи(PDF) 70 Page - TEXAS ADVANCED OPTOELECTRONIC SOLUTIONS |
|
|
|||||||||||||||||||||||||||||
CC2430DB датащи(HTML) 70 Page - TEXAS ADVANCED OPTOELECTRONIC SOLUTIONS |
|
70 / 212 page ![]() CC2430 Peripherals : Power Management and clocks CC2430 Data Sheet (rev. 2.1) SWRS036F Page 70 of 211 therefore the calibration may be disabled by setting register bit SLEEP.OSC32K_CALDIS to 1. Note that any ongoing calibration will be completed when a 1 is written to SLEEP.OSC32K_CALDIS. 13.1.4.4 Oscillator and Clock Registers This section describes the Oscillator and Clock registers. All register bits retain their previous values when entering PM2 or PM3 unless otherwise stated. CLKCON (0xC6) – Clock Control Bit Name Reset R/W Description 7 OSC32K 1 R/W 32 kHz clock oscillator select. The 16 MHz high frequency RC oscillator must be selected as system clock source when this bit is to be changed. 0 – 32.768 kHz crystal oscillator 1 – 32 kHz RC oscillator Note: this bit is not retained in PM2 and PM3. After re-entry to PM0 from PM2 or PM3 this bit will be at the reset value 1. 6 OSC 1 R/W System clock oscillator select: 0 – 32 MHz crystal oscillator 1 – 16 MHz high frequency RC oscillator This setting will only take effect when the selected oscillator is powered up and stable. If the XOSC oscillator is not powered up, it should be enabled by SLEEP.OSC_PD bit prior to selecting it as souorce. Note that there is an additional wait time (64 µs) from SLEEP.XOSC_STB set until XOSC can be selected as source. If RC osc is to be the source and it is powered down, setting this bit will turn it on. 5:3 TICKSPD[2:0] 001 R/W Timer ticks output setting, can not be higher than system clock setting given by OSC bit setting 000 – 32 MHz 001 – 16 MHz 010 – 8 MHz 011 – 4 MHz 100 – 2 MHz 101 – 1 MHz 110 – 500 kHz 111 – 250 kHz 2:1 - 00 R Reserved. 0 CLKSPD 1 R Clock Speed. Indicates current system clock frequency. The value of this bit is set by the OSC bit setting 0 – 32 MHz 1 – 16 MHz This bit is updated when clock source selected with the OSC is stable 13.1.5 Timer Tick generation The power management controller generates a tick or enable signal for the peripheral timers, thus acting as a prescaler for the timers. This is a global clock division for Timer 1, Timer 3 and Timer 4. The tick speed is programmed from 0.25 MHz to 32 MHz in the CLKCON.TICKSPD register. It should be noted that TICKSPD must not be set to a higher frequency than system clock. 13.1.6 Data Retention In power modes PM2 and PM3, power is removed from most of the internal circuitry. However parts of SRAM will retain its contents. The content of internal registers is also retained in PM2 and PM3. The XDATA memory locations 0xF000- 0xFFFF (4096 bytes) retains data in PM2 and PM3. Please note the exception as given below. The XDATA memory locations 0xE000- 0xEFFF (4096 bytes) and the area 0xFD56- |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |