| поискавой системы для электроныых деталей |
|
LAN9313 датащи(PDF) 44 Page - SMSC Corporation |
|
|
|||||||||||||||||||||||||||||
LAN9313 датащи(HTML) 44 Page - SMSC Corporation |
|
44 / 398 page ![]() Three Port 10/100 Managed Ethernet Switch with MII Datasheet Revision 1.2 (04-08-08) 44 SMSC LAN9313/LAN9313i DATASHEET 4.2.3.1 Port 2 PHY Reset A Port 2 PHY reset is performed by setting the PHY2_RST bit of the Reset Control Register (RESET_CTL) or the Reset bit in the Port x PHY Basic Control Register (PHY_BASIC_CONTROL_x). Upon completion of the Port 2 PHY reset, the PHY2_RST and Reset bits are automatically cleared. No other modules of the LAN9313/LAN9313i are affected by this reset. In addition to the methods above, the Port 2 PHY is automatically reset after returning from a PHY power-down mode. This reset differs in that the PHY power-down mode reset does not reload or reset any of the PHY registers. Refer to Section 7.2.9, "PHY Power-Down Modes," on page 96 for additional information. Port 2 PHY reset completion can be determined by polling the PHY2_RST bit in the Reset Control Register (RESET _ CTL) or the Reset bit in the P o rt x PHY Basic Contr o l Register (PHY_BASIC_CONTROL_x) until it clears. Under normal conditions, the PHY2_RST and Reset bit will clear approximately 110uS after the Port 2 PHY reset occurrence. Note: When using the Reset bit to reset the Port 2 PHY, register bits designated as NASR are not reset. Refer to Section 7.2.10, "PHY Resets," on page 97 for additional information on Port 2 PHY resets. 4.2.3.2 Port 1 PHY Reset A Port 1 PHY reset is performed by setting the PHY1_RST bit of the Reset Control Register (RESET_CTL) or the Reset bit in the Port x PHY Basic Control Register (PHY_BASIC_CONTROL_x). Upon completion of the Port 1 PHY reset, the PHY1_RST and Reset bits are automatically cleared. No other modules of the LAN9313/LAN9313i are affected by this reset. In addition to the methods above, the Port 1 PHY is automatically reset after returning from a PHY power-down mode. This reset differs in that the PHY power-down mode reset does not reload or reset any of the PHY registers. Refer to Section 7.2.9, "PHY Power-Down Modes," on page 96 for additional information. Port 1 PHY reset completion can be determined by polling the PHY1_RST bit in the Reset Control Register (RESET _ CTL) or the Reset bit in the P o rt x PHY Basic Contr o l Register (PHY_BASIC_CONTROL_x) until it clears. Under normal conditions, the PHY1_RST and Reset bit will clear approximately 110uS after the Port 1 PHY reset occurrence. Note: When using the Reset bit to reset the Port 1 PHY, register bits designated as NASR are not reset. Refer to Section 7.2.10, "PHY Resets," on page 97 for additional information on Port 1 PHY resets. 4.2.3.3 Virtual PHY Reset A Virtual PHY reset is performed by setting the VPHY_RST bit of the Reset Control Register (RESET_CTL) or Reset in the Virtual PHY Basic Control Register (VPHY_BASIC_CTRL). No other modules of the LAN9313/LAN9313i are affected by this reset. Virtual PHY reset completion can be determined by polling the VPHY_RST bit in the Reset Control Register (RESET_CTL ) or the Re set bit in the Virtua l PHY Basic Control Re gi ster (VPHY_BASIC_CTRL) until it clears. Under normal conditions, the VPHY_RST and Reset bit will clear approximately 1uS after the Virtual PHY reset occurrence. Refer to Section 7.3.3, "Virtual PHY Resets," on page 100 for additional information on Virtual PHY resets. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |