34 / 37 page

IMAGE SENSOR SOLUTIONS
34
Defect Classification
All values derived under nominal operating conditions at 40oC operating temperature.
Defect Type
Defect Definition
Number Allowed
Notes
Defective Pixel Under uniform illumination with mean pixel output at 80% of Vsat,
a defective pixel deviates by more than 15% from the mean value
of all pixels in its section.
12
1,2
Bright Defect
Under dark field conditions, a bright defect deviates more than
15mV from the mean value of all pixels in its section.
5
1,2
Cluster Defect
Two or more vertically or horizontally adjacent defective pixels.
0
2
Notes:
1. Sections are 252 (H) x 255 (V) pixel groups, which divide the imager into sixteen equal areas as shown
below.
2. For the color device, KAI-1010CM, a defective pixel deviates by more than 15% from the mean value
of all active pixels in its section with the same color.
1008,1018
1,1
1,255
1,510
1,1018
1008,255
1008,510
1008,1
1,765
1008,765
Test Conditions
Junction Temperature
(Tj) = 40oC
Integration Time
(tint) = 70msec
Readout Rate
(treadout) = 70msec
KAI-1010/1011 Rev 8 •