| поискавой системы для электроныых деталей |
|
AC-3 датащи(PDF) 10 Page - ABB |
|
|
|||||||||||||||||||||||||||||
AC-3 датащи(HTML) 10 Page - ABB |
|
10 / 25 page ![]() 2 /68 Low Voltage Products 1SBC100122C0202 Magnet System Characteristics for A... Contactors Contactor types: A... 9 12 16 26 30 40 45 50 63 75 95 110 Rated control circuit voltage U c – at 50 Hz V 24 ... 690 – at 60 Hz V 24 ... 690 Coil operating limits acc. to IEC 60947-4-1 0.85 ... 1.1 x U c (at θ < 55 °C) 0.85 ... 1.1 x U c (at θ < 70 °C) Please also refer to "Conditions for Use" Drop-out voltage in % of U c approx. 40 ... 65 % Coil consumption Average pull-in value 50 Hz VA 70 120 180 350 60 Hz VA 80 140 210 450 50/60 Hz(1) VA/VA 74/70 125/120 190/180 410/365 Average holding value 50 Hz VA/W 8/2 12/3 18/5.5 22/6.5 60 Hz VA/W 8/2 12/3 18/5.5 26/8 50/60 Hz(1) VA/W 8/2 12/3 18/5.5 27/7.5 Operating time between coil energization and: – N.O. contact closing ms 10 ... 26 8 ... 21 8 ... 27 10 ... 25 – N.C. contact opening ms 7 ... 21 6 ... 18 7 ... 22 7 ... 22 between coil de-energization and: – N.O. contact opening ms 4 ... 11 4 ... 11 4 ... 11 7 ... 15 – N.C. contact closing ms 9 ... 16 7 ... 14 7 ... 14 10 ... 18 (1) 50/60 Hz coils: see "Coil Voltage Code Table". Magnet System Characteristics for AF... Contactors Contactor types: AF... – – – – – – 45 50 63 75 95 110 Rated control circuit voltage U c – at 50 Hz V 48 ... 250 48 ... 250 – at 60 Hz V 48 ... 250 48 ... 250 – d.c. V 20 ... 250 20 ... 250 Coil operating limits acc. to IEC 60947-4-1 0.85 x U c min. ... 1.1 x Uc max. (at θ < 70 °C) Please also refer to "Conditions for Use" Drop-out voltage in % of U c min. 55 % Coil consumption Average pull-in value 50 Hz VA 210 350 60 Hz VA 210 350 d.c. W 190 400 Average holding value 50 Hz VA/W 7/2.8 7/3.5 60 Hz VA/W 7/2.8 7/3.5 d.c. W 2.8 2 Operating time between coil energization and: – N.O. contact closing ms 30 ... 100 30 ... 80 – N.C. contact opening ms 27 ... 95 27 ... 77 between coil de-energization and: – N.O. contact opening ms 30 ... 110 55 ... 125 – N.C. contact closing ms 35 ... 115 60 ... 130 A... and AF... Contactors Technical Data >> Coil Voltage Code Table ......................... page 0/1 >> Conditions for Use ................................ page 2/72 >> Terminal Marking and Positioning ........ section 8 Page extracted from eCatalogue: Contactors - Sales Engineer Version - Page 10 of 25 |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |