8 / 25 page ![]() 2 /64 Low Voltage Products 1SBC100122C0202 M 3 M 3 A... and AF... Contactors AL..., TAL... and AE..., TAE... Contactors Technical Data Main Pole - Utilization Characteristics acc. to IEC Contactor types: A... 9 12 16 26 30 40 45 50 63 75 95 110 AL..., TAL... 9 12 16 26 30 40 – – – – – – AE..., TAE..., AF... – – – – – – 45 50 63 75 95 110 Rated operational voltage U e max. V 690 1000 (690 for AF... contactors) 1000 Rated frequency limits Hz 25 ... 400 Conventional free-air thermal current I th acc. to IEC 60947-4-1, open contactors, θ ≤ 40 °C A 26 28 30 45 65 65 100 100 125 125 145 160 with conductor cross-sectional area mm2 4 446 16 16 35 35 50 50 50 70 Rated operational current I e / AC-1 for air temperature close to contactor θ ≤ 40 °CA 25 27 30 45 55 60 70 100 115 125 145 160 U e max. 690 V - 50/60 Hz θ ≤ 55 °C A 22 25 27 40 55 60 60 85 95 105 135 145 θ ≤ 70 °C (3) A 18 20 23 32 39 42 50 70 80 85 115 130 with conductor cross-sectional area mm2 2.5 4 4 6 10 16 25 35 50 50 50 70 Utilization category AC-3 for air temperature close to contactor < 55 °C Max. rated operational current I e AC-3 (1) 220-230-240 V A 912 1726 33404053 6575 96 110 3-phase motors 380-400 V A 912 1726 32373750 6575 96 110 415 V A 912 1726 32373750 6575 96 110 440 V A 912 1626 32373745 6570 93 100 500 V A 912 1422 28333345 5565 80 100 690 V A 79 10 17 (4) 21 (4) 25 (4) 25 35 43 46 65 82 1000 V A – ––– –––23 (6) 25 (6) 28 (6) 30 30 Rated operational power AC-3 (1) 1500 r.p.m. 50 Hz 220-230-240 V kW 2.2 3 4 6.5 9 11 11 15 18.5 22 25 30 1800 r.p.m. 60 Hz 380-400 V kW 4 5.5 7.5 11 15 18.5 18.5 22 30 37 45 55 3-phase motors 415 V kW 4 5.5 9 11 15 18.5 18.5 25 37 40 55 59 440 V kW 4 5.5 9 15 18.5 22 22 25 37 40 55 59 500 V kW 5.5 7.5 9 15 18.5 22 22 30 37 45 55 59 690 V kW 5.5 7.5 9 15 (4) 18.5 (4) 22 (4) 22 30 37 40 55 75 1000 V kW – ––– –––30 (6) 33 (6) 37 (6) 40 40 Rated operational current I e / AC-8a without thermal O/L relay - Ue 400 V - θ ≤ 40 °C A 12 16 22 30 40 50 – 63 85 95 120 140 Rated making capacity AC-3 10 x I e AC-3 acc. to IEC 60947-4-1 Rated breaking capacity AC-3 8 x I e AC-3 acc. to IEC 60947-4-1 Short-circuit protection for contactors without thermal O/L relay - Motor protection excluded (2) Ue < 500 V a.c. - gG type fuse A 25 32 32 50 63 80 100 125 160 160 200 Rated short-time withstand current I cw at 40 °C ambient temp., 1 s A 250 280 300 400 600 1000 1320 1320 in free air, 10 s A 100 120 140 210 400 650 800 800 from a cold state 30 s A 60 70 80 110 225 370 500 500 1 min A 50 55 60 90 150 250 350 350 15 min A 26 28 30 45 65 110 110 135 135 160 175 Maximum breaking capacity (5) cos ϕ = 0.45 at 440 V A 250 420 820 (5) 900 1300 1160 (cos ϕ = 0.35 for Ie > 100 A) at 690 V A 90 (5) 170 (5) 340 (5) 490 630 800 Heat dissipation per pole I e / AC-1 W 0.8 1 1.2 1.8 2.5 3 2.5 5 6.5 7 6.5 7.5 I e / AC-3 W 0.1 0.2 0.35 0.6 0.9 1.3 0.65 1.3 1.5 2 2.7 3.6 Max. electrical switching frequency – for AC-1 cycles/h 600 600 (300 for AF..., AE... TAE...) 300 – for AC-3 cycles/h 1200 600 (300 for AF..., AE... TAE...) 300 – for AC-2, AC-4 cycles/h 300 150 150 Mechanical durability – millions of operating cycles 10 (5 for AE... and TAE... contactors) – max. switching frequency cycles/h 3600 (300 for AF... contactors) (1) For the corresponding kW/A or hp/A values of 1500 r.p.m., 50Hz or 1800 r.p.m., 60Hz, 3-phase motors, see "Motor Rated Operational Powers and Currents". (2) For the protection of motor starters against short circuits, see "Coordination with Short-circuit Protection Devices". (3) Unauthorized for TAL..., TAE... contactors. (6) AF... contactors excluded. A... and AF... Contactors AL..., TAL... and AE..., TAE... Contactors Technical Data { >> Electrical Durability Curves .................. page 2/81 >> Motor Rated Powers and Currents ....... page 0/0 >> Coordination with SCPD ........................ section 7 (4) AC-3, 690 V values for AL... and TAL... contactors Types AL 26 AL 30 AL 40 TAL 26 TAL 30 TAL 40 Rated current I e A 13 18 21 Rated power kW 11 15 18.5 (5) Max. breaking capacity for AL... and TAL... contactors Types AL 9 ... AL 16 AL 26 AL 30, AL 40 TAL 9 ... TAL 16 TAL 26 TAL 30, TAL 40 440 V A 250 420 470 690 V A 100 106 175 Page extracted from eCatalogue: Contactors - Sales Engineer Version - Page 8 of 25 |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |