| поискавой системы для электроныых деталей |
|
LM81 датащи(PDF) 13 Page - National Semiconductor (TI) |
|
|
|
|||||||||||||||||||||||||||||
LM81 датащи(HTML) 13 Page - National Semiconductor (TI) |
|
13 / 33 page ![]() Functional Description (Continued) 2.2 Serial Bus Interface The Serial Bus control lines consist of the SMBData (serial data), SMBCLK (serial clock) and A0-A1 (address) pins. The LM81 can operate only as a slave. The SMBCLK line only controls the serial interface, all other clock functions within LM81 such as the ADC and fan counters are done with a separate asynchronous internal clock. When using the Serial Bus Interface a write will always consist of the LM81 Serial Bus Interface Address byte, fol- lowed by the Internal Address Register byte, then the data byte. There are two cases for a read: 1. If the Internal Address Register is known to already be at the desired Address, simply read the LM81 with the Serial Bus Interface Address byte, followed by the data byte read from the LM81. 2. If the Internal Address Register value is unknown, or if it is not the desired value, write to the LM81 with the Serial Bus Interface Address byte, followed by the Internal Address Register byte. Then restart the Serial Commu- nication with a Read consisting of the Serial Bus Inter- face Address byte, followed by the data byte read from the LM81. The default Serial Bus address of the LM81 is set to 010 11(A1)(A0). All bits, except for A0 and A1, can be changed by writing to the Serial Bus address register. A0 and A1 will always reflect the state of the A0 and A1 input pins. All of these communications are depicted in the Serial Bus Interface Timing Diagrams as shown in Figure 5. Serial Bus Timeout can be initiated by holding the SMBCLK and/or SMBData lines low for greater than t TIMEOUT (35 ms max). Serial Bus Timeout resets the serial bus interface circuitry to the idle state and readies the LM81 for a new serial bus communication. DS100072-8 (a) Serial Bus Write to the Internal Address Register followed by the Data Byte DS100072-9 (b) Serial Bus Write to the Internal Address Register Only DS100072-10 (c) Serial Bus Read from a Register with the Internal Address Register Preset to Desired Location FIGURE 5. Serial Bus Timing www.national.com 13 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |